DC Inverter U-match Series Cassette Type Unit
5
3.2 Selection of the Installation Location
WARNING!
The unit must be installed where strong enough to withstand the weight of the unit and fixed securely,
otherwise the unit would topple or fall off.
CAUTION!
① .
Do not install where there is the danger of combustible gas leakage.
② .
Do not install the unit near heat source of heat, steam, or flammable gas.
③ .
Children under 10 years old must be supervised not to operate the unit.
Decide the installation location with the customer as follows:
3.2.1 Indoor Unit
Select an installation site where the following conditions are fulfilled and that meets your
customer’s approval.
(1). Obstruct should be put away from the intake or outlet vent of the indoor unit so that the
airflow can be blown through all the room.
(2). Make sure that the installation meets the requirement of the schematic diagram of
installation spaces.
(3). Select the place where can stand 4 times of the weight of the indoor unit and would not
increase the operating noise and vibration.
(4). The horizontality of the installation place should be guaranteed.
(5). Select the place where is easy to drain out the condensate water, and connect with outdoor
unit.
(6). Make sure that there are enough space for care and maintenance, and the height fall
between the indoor unit and ground is above 1800mm.
(7). When installing the suspension bolt, check if the installation place can stand 4 times of the
weight of the unit. If not, reinforce it before installation.
Note: There will be large amount of greasy dirt accumulated on the fan, heat exchanger and water
pump located in the dinning room and kitchen, which would reduce the capacity of the heater
exchanger, lead to leakage and abnormal operation of the water pump.