Air-conditioner Air switch capacity
09K
1
12K
16A
0A
21
Requirements for electric connection
Safety precaution
Grounding requirement
1.
3.
Must follow the electric safety regulations when installing the unit.
air switch.
Make sure the power supply matches with the requirement of air conditioner.
4.
5.
Unstable power supply or incorrect wiring or malfunction. Please install proper
power supply cables before using the air conditioner.
Properly connect the live wire, neutral wire and grounding wire of power socket.
Be sure to cut off the power supply before proceeding any work related to
electricity and safety.
7.
8.
If the supply cord is damaged, it must be replaced by the manufacturer, its
tion cable away from the copper tube.
The temperature of refrigerant circuit will be high, please keep the interconnec-
9. The appliance shall be installed in accordance with national wiring regulations.
2.
for other purposes.
The yellow-green wire in air conditioner is grounding wire, which can't be used
3.
grounding with specialized grounding device by a professional. Please make
sure it is always grounded effectively, otherwise it may cause electric shock.
4.
5.
The appliance must be positioned so that the plug is accessible.
An all-pole disconnection switch having a contact separation of at least 3mm in
6.
all poles should be connected in fixed wiring. For models with a power plug, make
sure the plug is within reach after installation
Including an air switch with suitable capacity, please note the following table. Air
switch should be included magnet buckle and heating buckle function, it can
protect the circuit-short and overload. (Caution: please do not use the fuse only
for protect the circuit)
The grounding resistance should comply with local electric safety regulations.