Gree GIS409AC Скачать руководство пользователя страница 23

21

 

After tighten the screw, slight pull the wire and confirm whether is it firm or not.

 

 

The cover plate must be fixed, and tighten the connection wire, if it is poor installed, that 

Install indoor unit

NOTE:

When connecting the electric wire if the wire length is not enough, please contact with

the authorized service shop to buy a exclusive electric wire that is long enough and the

joint on the wire are not allowed.

The electric wiring must be correctly connected, wrong connection may cause spare parts

malfunction.

Tighten the terminal screw in order to prevent loose.

If the earth wire is wrong connection, that may cause electric shock.

the dust, moisture may enter in or the connection terminal will be affected by outside force,

and will cause fire or electric shock.

右后

4.

2.

3.

 

1.

⑴ 
⑵ 

1.
2.

Install the indoor unit

The piping can be lead out from right, right rear, left

left rear.

When routing the piping and wiring from the left

or right side of indoor unit, cut off the tailings

from the chassis in necessary(Show in Fig.7)

Cut off the tailings 1 when routing the wiring only;

Cut off the tailings 1 and tailings 2 when routing

both the wiring and piping. 

Take out the piping from body case, wrap the piping

electric wire, water pipe with tape and pull them

through the piping hole (As show in Fig.8)

Hange the mounting slots of the indoor unit on the

upper tabs of the rear panel and check if it is firm

enough.(As show in Fig.9)

The height of the installed location should be 2. m

or more from the floor.

Install the connection pipe

Align the center of the piping flare with the relevant valve.

Screw in the flare nut by hand and then tighten the

nut with spanner and torque wrench refer to the 

following:

NOTE: Firstly connect the connection pipe to indoor unit, then to outdoor unit; pay attention

to the piping bending, do not damage the connection pipe; the joint nut couldn't tighten too

much, otherwise it may cause leakage.

Spanner

Torque 

wrench

Piping

Taper nut

Indoor unit piping

Fig.9

Mounting

plate

Fixing hook

Mounting 

baord

Right

Right rear

Fig.8

Left rear

Left

Fig.7

Tailing 1

Tailing 2

Finally wrap it

with tape

Gas side piping

insulation

Water drainage pipe

Liquid side

Piping insulation

Gas side pipe

External connection

electric wire
Liquid side piping

          (N·m)

Ф

6

Ф

9.52

Ф

12

30

40

15~20

45

~55

Ф

16

60~65

Ф

19

70~75

Hex nut diameter

Tightening torque

5

Содержание GIS409AC

Страница 1: ...oosing Gilman air conditioner For correct operation and keep it carefully for consultation please read this owner s manual carefully before operating the unit Gilman AIR CONDITIONERS GIS412AE GIS412AC...

Страница 2: ...tion of such waste separately for special treatment is necessary Thank you for choosing Gilman air conditioner please read this owner s manual carefully before operating the unit and keep it carefully...

Страница 3: ...en for a long time while operating the air conditioner It can decrease the air conditioning capacity Don t block the air intake or outlet vents of both the outdoor and indoor units It can decrease the...

Страница 4: ...ver of left right direction Louver of upward downward direction Don t insert your hands or stick into the air intake or outlet vents Otherwise it will cause accident Don t blow the wind to animals and...

Страница 5: ...s way to increase room temperature This is the heat pump heating principle its heating capacity will be reduced due to outdoor temperature decrease If outdoor temperature becomes very low please opera...

Страница 6: ...ature for cooling unit is 18 43 for cooling and heating unit is 7 43 Gentle Breeze In the following situation the indoor unit may blow gentle breeze and the guide louver rotate to a certain position 1...

Страница 7: ...unit Air in Air out Outdoor unit Wireless remote control Air in Air out Power cable Remote control Front panel Filter Guide louver Wall pipe Bind tape Connection wire Drainage pipe Cool Dry Fan Heat...

Страница 8: ...Sleep function set up the signal of Sleep will display In this mode the time of timer can be adjusted Under Fan and Auto modes this function is not available Press this button Auto Low Middle High sp...

Страница 9: ...setting temperature increasing Press this button can set up the temperature when unit is on Continuously press and hold this button for more than 2 seconds the corresponding contents will be changed r...

Страница 10: ...sed 1 minute Hold pressing or button 2 seconds later it quickly change the way of change is During the initial 2 5 seconds ten numbers change in the one place of minute then the one place is constant...

Страница 11: ...ed temperature It is unnecessary to set the temp at AUTO mode 4 Pressing FAN button set fan speed can select AUTO FAN LOW MID and HIGH 5 Pressing button to select the swing 1 Press SLEEP button to set...

Страница 12: ...on it in which case press any button the mark will Operation of wireless remote control 1 Changing batteries and notices 10 Slightly to press the place with along the arrowhead direction to push the b...

Страница 13: ...se the displayer indicator light will be off if the AC receives this signal Displayer indicator light control of indoor unit display on the remote controller screen by this signal Emergency operation...

Страница 14: ...oid hurt your fingers Take down the air filter At the slot of surface panel to open an angle pull the air filter downward and take it out please see the Fig 4 a b To clean the dust adhering to the fil...

Страница 15: ...ct the dealer Clean and care Check before use Check that whether ground wire is properly connected or not Maintain after use Turn main power off Clean the filter and indoor and outdoor units bodies Cl...

Страница 16: ...m still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow can be heard during the operation The air conditioner is started when it is runni...

Страница 17: ...n its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged If water leakage...

Страница 18: ...sh water or something into unit There is an abnormal heat in power supply cord and power plug Stop running and pull out of the plug In HEAT mode when the temperature of indoor heat exchanger is very l...

Страница 19: ...lation Important Notices Basic Requirements For Installation Position Install in the following place may cause malfunction If it is unavoidable contact with service center please Place where strong he...

Страница 20: ...cut off and be fix it by screw otherwise it would cause electric shock 3 The earth resistance should accord to the National Criterion 4 The user power must offer the reliable earthing terminal Please...

Страница 21: ...Space to the wall Air outlet side Space to the floor Above Above Above Above Above The dimensions of the space necessary for correct installation of the appliance including the minimum permissible di...

Страница 22: ...lant to the outdoor side 2 Insert the piping hole sleeve into the hole to prevent the connection piping and wiring from being damaged when passing through the hole Install the water drainage pipe 1 Fo...

Страница 23: ...Cut off the tailings 1 and tailings 2 when routing both the wiring and piping Take out the piping from body case wrap the piping electric wire water pipe with tape and pull them through the piping ho...

Страница 24: ...g Ensure wire has been fixed well Install the handle connector 5 1 0 X 10 pa 76cmHg 10 Fig 1 Connect charging hose of manifold valve to charge end of low pressure valve both high low pressure valves m...

Страница 25: ...It may cause electric malfunction or damage the part Is the electric wiring and piping connection installed correctly and securely It may cause electric malfunction or damage the part Has the unit bee...

Страница 26: ...s for silver ion filter it is invalid when its surface becomes according to the installation instruction Pay special attention to that silver Take out the healthy filter before cleaning and reinstall...

Страница 27: ......

Страница 28: ...66129915435...

Отзывы: