
32
Maintenance
Service Manual
16. Remove condenser and evaporator
17.Remove support rod
18.Remove water tray sub-assy
Remove 2 screws on the support rob
and then remove the support rod.
Lift it upwards and then remove the evaporator
and the condenser.
Remove one screw connecting water tray
and chassis, loose 5 clasps connecting
the chassis and then remove the water
tray.
a
b
weld spot
condenser and evaporator
screw
screw
support rod
clasp
water tray sub-assy
Unsolder the spot weld between suction pipe,
discharge pipe and evaporator, condenser,
and remove suction pipe and discharge pipe.
Unsolder the spot weld between capillary
sub-assy and condenser, evaporator, and then
remove capillary sub-assy.
Note:
1. Before unsoldering the spot weld, please
confirm the refrigerant is discharged completely.
2. When unsoldering the spot weld of capillary,
wrap the capillary with wet cloth to prevent
damage to capillary due to high temperature.
Step
Procedure