background image

1

1

 

 

Emergency Operation

Emergency Operation

When the wireless remote control is lost or damaged, please use the manual switch, at this
time, it is running in Auto Run mode that will not change the temperature setting value and
fan speed.

The manual switch can be operated as follow:

At operation: When the unit stopped running, 
press ON/OFF button, unit will enter into AUTO 
RUN mode. The microcomputer will accord to 
the room temperature to select the (COOL, 
HEAT, FAN) mode automatically, to obtain the 
comfortable effect.

At stopping: When the unit is running, press the
ON/OFF button of the manual switch, the unit
will stop work.

The code switch can be operated as follow:

At operation: When the unit is stopped running,
adjust the code switch to AUTO, the unit will 
enter into AUTO RUN mode. The microcomputer
will accord to the room temperature to select the
(COOL, HEAT, FAN) mode automatically, to 
obtain the comfortable effect.

At stopping: When the unit is running, adjusts
the code switch to STOP position, the unit will
stop work. 

Code Switch

Manual Switch

AUTO/STOP

only for some models

Содержание Cozy

Страница 1: ...fe Split Air Conditioner Owner s Manual Residential Air Conditioners Thank you for choosing Residential Air Conditioners please read this owner s manual carefully before operation and retain it for future reference ...

Страница 2: ...lation service Notices for Installation Installation Drawing Installation of Indoor Unit Installation of Outdoor Unit Check after Installation and Operation Test This symbol stands for the items should be forbidden This symbol stands for the items should be followed Emergency operation The figures in this manual may be different with the material objects please refer to the material objects for re...

Страница 3: ...e the accumulated dusts that may cause over heating or fire Never splice the power cord or use an extended cord It can cause overheating or fire When having a burning smell or smoke please turn off the power supply and contact with the service center If the abnormity still exists the unit may be damaged and may cause electric shock or fire Please read the following carefully before operating Notic...

Страница 4: ... to them Don t insert your hands or stick into the air intake or outlet vents Don t use the air conditioner for other purposes such as drying clothes preserving foods etc To adjust the airflow direction appropriately When operating the unit to adjust the vertical and lateral air flow direction by use of remote controller Swing louver Guide louver Please don t cut off or damage the power cords and ...

Страница 5: ... to outdoor and discharged so that indoor ambient temperature decreased its cooling capacity will increase or decrease by outdoor ambient temperature If the unit is running in COOL mode and in low temperature there will be frost formed on the heat exchanger when indoor heat exchanger temperature decreased below 0 the indoor unit microcomputer will stop compressor running and protect the unit Princ...

Страница 6: ...Air out Front panel Filter Guide louver Bind tape Connection wire Drainage pipe Remote control Outdoor unit Air in Air out Power cable Wall pipe ON OF F MODE FAN SW I NG I FEE L SLEE P TE M P TI MER ON CLOCK T OF F IMER TURBO LIGHT X FAN F C H O U R ONOFF ...

Страница 7: ...se temperature setting FAN Press it set swing angle TIMER ON SWING TIMER OFF CLOCK X FAN page 9 TEMP page 9 TURBO page 9 SLEEP page 9 LIGHT Press it to set fan speed Press it to set auto on timer Press it to set auto off timer Press it set clock 1 7 Press it to set HEALTH or AIR function 8 I FEEL Page 8 4 3 2 5 6 11 13 12 16 10 14 9 15 Operation of Remote Controller 3 15 5 4 14 7 16 13 12 9 8 11 1...

Страница 8: ...nt operation mode icon AUTO COOL DRY FAN or HEAT only for heat pump models will show 17 is displayed when pressing the up down swing down button Press this button again to clear the display 21 Up down swing icon After pressing TIMER button ON or OFF will blink This area will show the set time SET TIME display 23 Pressing TEMP button set temperature ambient temperature outdoor ambient temperature a...

Страница 9: ...essing the TURBO button Press this button again to clear the display TURBO icon 28 is displayed when pressing the X FAN button Press this button again to clear the display X FAN icon 27 Press FAN button to select the desired fan speed setting AUTO Low Med High Your selection will be displayed in the LCD windows except the AUTO fan speed FAN SPEED display 29 29 30 26 27 28 Operation of Remote Contr...

Страница 10: ...MODE This button is used for setting Fan Speed in the sequence that goes from AUTO to then back to Auto FAN 1 4 3 2 5 Operation of Remote Controller Press this button to turn on the unit Press this button again to turn off the unit Press this button to decrease set temperature Holding it down above 2 seconds rapidly decreases set temperature In AUTO mode set temperature is not adjustable Press thi...

Страница 11: ... then by 10 minutes every 0 5 second During blinking after setting press CLOCK button again to confirm the setting and then 12 will be constantly displayed TIMER ON TIMER OFF 11 13 TURBO 10 14 Operation of Remote Controller TEMP Press this button to initiate the auto ON timer To cancel the auto timer program simply press this button again After press of this button disappears and ON blinks 00 00 i...

Страница 12: ...ng batteries Replacement of Batteries Press and buttons simultaneously to lock or unlock the keypad If the remote controller is locked is displayed In this case pressing any button blinks three times At unit OFF press MODE and buttons simultaneously to switch between and Combination of and buttons About lock 17 About Back lighting Function About HEALTH function COLD PLASMA Turn on the unit start u...

Страница 13: ...select the COOL HEAT FAN mode automatically to obtain the comfortable effect At stopping When the unit is running press the ON OFF button of the manual switch the unit will stop work The code switch can be operated as follow At operation When the unit is stopped running adjust the code switch to AUTO the unit will enter into AUTO RUN mode The microcomputer will accord to the room temperature to se...

Страница 14: ...ont panel Note Do not immerse the front panel into water so as to protect microprocessor components and circuit diagram on the front panel Care and Cleaning 12 Clean the air filter Take down the air filter Lift up the front panel Pull the air filter downwards to take it off as shown in Fig a b Use a vacuum cleaner to remove dust If the filters are dirty wash them with warm water and mild detergent...

Страница 15: ...filters and Clear obstructions from the outdoor unit Check if the batteries of remote controller are replaced Check if the installation stand of the outdoor unit is damaged If damaged consult the technicians bodies of indoor and outdoor units Repaint the rubiginous place on the outdoor unit to prevent it from spreading Care and Cleaning ...

Страница 16: ...s emitted in COOL mode During cooling operation a thin mist may be seen emitted from the indoor unit due to high room temperature and humidity After a period of time the mist will disappear with the decrease of room temperature and humidity 14 The air conditioner is not expected to be serviced by users Incorrect repair may cause electric shock or fire so please contact an authorized service center...

Страница 17: ...heat sources in the room the the Check if there is magnetic or electrical interference near the unit that may affecting operation of the controller In this case pull the plug out and reinsert it Is the remote controller within its operating range or obstructed Check the condition of the batteries and replace them if necessary Check if the remote controller is damaged Water leakage of indoor unit W...

Страница 18: ...s immediately stop all operations cut off the power supply and contact the authorized personnel Strong odours are emitted during operation The air switch or protection switch often trips Power cord and power plug is overheating n o i t a r e p o p o t S and cut off the power supply Troubleshooting Phenomenon Troubleshooting Indoor unit can not blow air Moisture on air outlet C5 Malfunction of conn...

Страница 19: ...ure that they do not play with the appliance Notices for Installation Caution Installation Site Instructions 17 The unit should be installed only by authorized service center according to local or government regulations and in compliance with this manual Before installing please contact with local authorized maintenance center If the unit is not installed by the authorized service center the malfu...

Страница 20: ...witch with a contact separation of at least 3mm in all poles should be connected in fixed wiring The unit should be reliably earthed and connected to an exclusive earth device by the professionals 4 The air switch must have the functions of magnetic tripping and heat tripping to prevent short circuit and overload Make sure the live wire neutral wire and earth wire in the family power socket are pr...

Страница 21: ...g may cause electric shock 3 The earth resistance should accord to the national criterion 4 The power must have reliable earthing terminal Please do not connect the earthing wire with the following W e p i p s a G e p i p r e t a Contamination pipe Other place that professional personnel consider is unreliable 5 The model and rated values of fuses should accord with the silk print on fuse cover or...

Страница 22: ... Above Space to the wall Space to the wall Space to the wall 50cm Above 3 0 c m A b o v e 50cm Above 0 2 0 15cm 15cm 300 cm 2 15 cm Space to the floor Air outlet side Space to the obstruction Air outlet side Air inlet side 2 0 0 c m A b o v e 30cm Above Above m c 250 Space to the wall ...

Страница 23: ... 2 Installation of Drain Hose Connect the drain hose to the outlet pipe of the indoor unit Bind the joint with rubber belt Put the drain hose into insulating tube bulge distortion outlet pipe of indoor unit insulating tube connected insulating tube drain hose outlet pipe of indoor unit drain hose outlet pipe of indoor unit outlet pipe of indoor unit rubber belt rubber belt rubber belt Flooded Ф m ...

Страница 24: ...k Connecting Indoor and Outdoor Electric Wires 22 Installation of Indoor Unit 1 Open the front panel upwardly 2 Screw off the fixing screw of cover plate and screw off cover plate 3 Put the power connection cable through the back of indoor unit wire hole and take it out 4 All the wiring should be connected according to the circuit diagram on the unit 5 Put the power connection cable the section wh...

Страница 25: ...site should be 250cm or more above the floor Installation of Connection Pipe Align the center of the pipe flare with the related valve Screw in the flare nut by hand and then tighten the nut with spanner and torque wrench by referring to the following NOTE Connect the connection pipe to indoor unit at first and then to outdoor unit Handle pi ping bending with care Do not damage the connection pipe...

Страница 26: ...air coming inside If noise of vacuum pump has been changed the reading of multimeter is 0 Then tighten the nut 5 Keep vacuuming for more than 15mins and make sure the reading of multi meter is 6 Fully open high low pressure valves 7 Remove charging hose from charging end of low pressure valve 8 Tighten lid of low pressure valve As shown in Fig 10 Fig 10 Schematic diagram being reference only pleas...

Страница 27: ...e Is the voltage in accordance with the rated voltage marked on the nameplate It may cause electric malfunction or damage the unit Is the electric wiring or piping connection installed correctly and securely It may cause electric malfunction or damage the parts Has the unit been securely earthed It may cause electrical leakage Is the power cord specified It may cause electric malfunction or damage...

Страница 28: ...lthy filter and reinstall it after cleaning according to the installation instruction Do not use brush or hard objects to clean the filter After cleaning be sure to dry it in the shade The general service life for the healthy filter is about one year under normal condition As for silver ion filter it is ineffective when its surface becomes black green This supplementary instruction is provided for...

Страница 29: ...additional refrigerant charging amount on the 1 Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging amount per meter 2 When the length of connection pipe is above 5m add refrigerant according to the prolonged length of liquid pipe The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe See Sheet 2...

Страница 30: ...er of connection pipe mm Indoor unit throttle Outdoor unit throttle Liquid pipe Gas pipe Cooling only cooling and heating g m Cooling only g m Cooling and heating g m Ф6 Ф9 5 or Ф12 20 15 20 Ф6 or Ф9 5 Ф16 or Ф19 50 15 50 Ф12 Ф19 or Ф22 2 100 30 120 Ф16 Ф25 4 or Ф31 8 170 60 120 Ф19 250 250 250 Ф22 2 350 350 350 Configuration of connection pipe and additional volume of refrigerant ...

Страница 31: ......

Страница 32: ...Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com GREE ELECTRIC APPLIANCES INC OF ZHUHAI 66129912628 ...

Отзывы: