CASSET TE B SERIES

 OWNERS MANUAL - INDOOR UNIT

 |

 19

OPERATION OF REMOTE CONTROLLER (Continued)

NOTE

• During this procedure, if no button is pressed within 

10 seconds, remote controller will automatically exit 
the sleep curve setting and resume original display. 
If ON/OFF, SLEEP, COOLING or HEATING button 
is pressed during the setting or inquiry procedure, 
remote controller will also exit the sleep curve 
setting.

Press this button to turn off display light on indoor unit. 
“ “ icon on remote controller disappears.
Press this button again to turn on display light. “ “ icon 
is displayed.

Press this button to see the indoor set temperature on 
the unit’s display. The setting on remote controller is 
selected circularly as below:

NOTE

• Under status, you can set T-OFF or T-ON simultane-

ously.

• Before setting T-ON or T-OFF, please set the clock.
• After starting T-ON or T-OFF, set to “circulating” 

mode.

• Your unit will be turned on or turned off according 

to setting. ON/OFF button has no effect on setting. 
If you don’ t need this function, please use remote 
controller to cancel it.

Press this button to start I FEEL function and “ “ will be 
displayed on the remote controller. When set, the remote 
controller will send the detected ambient temperature 
to the controller and the unit will automatically adjust 
the indoor temperature according to the detected 
temperature. Press this button again to cancel I FEEL 
function and “ “ will disappear.
• Put the remote controller near the user when this 

function is set. Avoid putting the remote controller 
near an object of high or low temperature. When 
I FEEL function is turned on, the remote controller 
should be put where the indoor unit can receive the 
signal sent by the remote controller.

Press this button to set clock time. “ “ icon on remote 
controller will blink. Press “ “ or “ “ button within 5s 
to set clock time. Pressing the “ “ or “ “ button, clock 
time will increase or decrease 1 min. If you hold “ “ or “

“ button for longer than 2s the time will change rapidly.

Release this button when reaching your required time. 
Press “CLOCK” button to confirm the time. “ “ icon 
stops blinking.

NOTE

• This is a 24 hour clock.
• A delay of more than 5s in setting the ON and OFF 

times will cancel the set-up and you will have to 
start over. Operation for TIMER ON/TIMER OFF is 
the same.

Under COOL or HEAT mode, press this button to start 
up sleep function. “ “ icon is displayed on remote 
controller. Press this button again to cancel sleep
function and “ “ icon will disappear.

Содержание CAS12HP230V1BC

Страница 1: ...LS CAT NO GREE_CASSETTE B_OWNERS_11102022 Thank you for choosing our product Please read this Owner s Manual carefully before operation and retain it for future reference To download an electric versi...

Страница 2: ...other GREE installed products worldwide has gone into your unit Please read this owner s manual carefully before operation and retain it for future reference TABLE OF CONTENTS Nomenclature 3 Safety Pr...

Страница 3: ...l Electrical Rating 230V 208 230V 1PH 60Hz Style Color Designation Product Type O Outdoor Units C Indoor Cassette D Indoor Slim Duct F Indoor Floor Ceiling Model Type HP Heat Pump Capacity 12 12 000 B...

Страница 4: ...hanced installation reliability or operation NOTE Your actual air conditioning heating system and related devices may differ from the images shown in this manual WARNING This appliance is not intended...

Страница 5: ...g be careful not to splash water on the unit Doing this may cause electric shock or damage to unit Do not use or place any flammable combustible or noxious substance next to the unit In the event of a...

Страница 6: ...ired Controller 6 Remote Controller 7 Big handle 8 Liquid Pipe 9 Gas pipe 10 Drainage pipe 11 Front Board Indoor unit Outdoor unit 2 3 4 7 5 6 1 8 9 10 11 Air inlet Air outlet Fig 1 DISCLAIMER Not all...

Страница 7: ...it It then adjusts airflow and temperature accordingly for ultimate personal comfort ADJUSTABLE AIRFLOW The Cassette B Series system has a four directional airflow for maximum comfort The indoor unit...

Страница 8: ...ections and system parameters are stored in non volatile memory These parameters are retained during a power failure When power is returned the Cassette B Series system will automatically return to th...

Страница 9: ...when I DEMAND function is set Display when WiFi function is set Lock out status display when lock out function is set Display when up and down swing function is set Icon of follower controller it will...

Страница 10: ...er the lock state in which case any other buttons won t respond Repress them for 5s to quit this state Under OFF state the Celsius and Fahrenheit scales can be switched by pressing MODE and for 5s Und...

Страница 11: ...Cooling Dry Fan or Heating mode the temperature setting range is 61 F 86 F 16o C 30o C IntheAutomode thesettingtemperatureisunadjustable 3 4 Fan Setting Under the ON State of the unit each time you p...

Страница 12: ...ion Swing setting is shown as Fia 9 NOTE 1 Use the Swing setting procedure to initiate Sleep Turbo or X fan 2 Oncethesettingiscompleted press SWING ENTER to initiate another setting or it will automat...

Страница 13: ...indoor unit will be automatically evaporated to avoid mildew In the Cooling or Dry mode press FUNCTION till the unit enters the X fan setting interface and then press SWING ENTER to activate When the...

Страница 14: ...Demand setting interface Press SWING ENTER to confirm the setting I Demand off When the I Demand function is activated press FUNCTION to enter the I Demand setting interface After that press SWING ENT...

Страница 15: ...e seconds to go to the commissioning status Under this status adjust the display in the temperature display area to 00 through the button MODE and then adjust the option of the temperature sensor in t...

Страница 16: ...SERIES OWNERS MANUAL INDOOR UNIT 16 OPERATION OF REMOTE CONTROLLER Buttons on remote controller Introduction for icons on display screen Remote lock out DISCLAIMER All functions are not available for...

Страница 17: ...ate in a fan only mode no heating or cooling and all indicators will be off When all indicators are off press FAN button to adjust fan speed Press button to adjust fan blowing angle When selecting HEA...

Страница 18: ...down at maximum angle Select and fan modulation will stop at that fixed position Horizontal louver will stop at the fixed position Select will not modulate but blow at a fixed angle Hold button more...

Страница 19: ...on the remote controller When set the remote controller will send the detected ambient temperature to the controller and the unit will automatically adjust the indoor temperature according to the det...

Страница 20: ...ither Sleep function and 46 F 8 C heating function can t operate at the same time If 46 F 8 C heating function has been set under heat mode pressing the SLEEP button will cancel 46 F 8 C heating funct...

Страница 21: ...e unit is installed in a room where the air is extremely contaminated As a yardstick for yourself consider cleaning the filter once a half year If dirt becomes impossible to clean change the air filte...

Страница 22: ...the HEAT mode In order to prevent cold air from blowing out it may take several minutes before the fan starts This is normal Air conditioner isn t coming on Power failure Wait until power recovery Lo...

Страница 23: ...s clippings and other debris can stick to coil fins and make the unit work up to 15 harder 5 Rearrange the room Furniture that obstructs the airflow needs to be removed or rearranged accordingly 6 Try...

Страница 24: ..._____________________ Serial No ___________________________________ Outdoor Model No _____________________________ Serial No ___________________________________ Owner Name ____________________________...

Страница 25: ...U S CONTACT INFORMATION TRADEWINDS LLC E mail info twciimate com Contractor Support 888 850 7928 I Mon Fri 8 AM 5 PM EST G R E E C O M F O R T C O M...

Отзывы: