3.12 Energy Saving Function Setting 

Turn on energy saving function:
1. Energy Saving Setting for Cooling
• When the unit runs under the COOL or DRY mode, 

press FUNCTION button to select “SAVE” function 
option,“SAVE” will be flashing on the display. Press   
or   to adjust the lower limit, then press the SWING/
ENTER button to activate.

2. Energy Saving Setting for Heating
• When the unit runs under the HEAT mode, press 

FUNCTION button to select “SAVE” function option,  
“SAVE” will be flashing on the display. Press 

 

or   

to adjust the upper limit, then press SWING/ENTER 
button to activate.

NOTE:

• Under energy saving setting mode, press “MODE” 

button to switch the energy saving setting for COOL 
or HEAT mode.

Turn off energy saving function:
• If energy saving function has been set, press 

FUNCTION button on the panel to select “SAVE” 
function option. When 

SAVE

 icon flashes, if you 

press SWING/ENTER button without pressing   or 

 button, energy saving function will be canceled; if 

you press SWING/ENTER button after pressing 

 

or   

button, energy saving function will be activated.

3.13 X-fan Setting 

• X-fan function: After the unit is turned off, the water 

in evaporator of indoor unit will be automatically 
evaporated to avoid mildew.

• In the Cooling or Dry mode, press FUNCTION till the 

unit enters the X-fan setting interface and then press 
SWING/ENTER to activate.

• When the X-fan function is activated, press and hold 

FUNCTION until”X-FAN” appears then press SWING/
ENTER to cancel.

• X-fan function setting is as shown in Fig.15

NOTE:

1.  When the X-fan function is activated, turning off 

the unit by pressing ON/OFF or by the remote 
controller, the indoor fan will run at the low fan 
speed for 2 min, with “X-FAN” displayed on the 
LCD. If the X-fan function is deactivated, the 
indoor fan will be turned off directly.

2.  X-fan function is unavailable in the Fan or Heating mode.

3.14 Quiet Function Setting 

Turn on quiet function:
• Under unit on status, press FUNCTION button on the 

panel to select “Quiet” function option. When“Quiet” 
or “Auto quiet” flashes, it enters quiet function setting 
mode. Press   or   button to switch between “Quiet” 
and “Auto quiet” function. Then press SWING/ENTER 
button to activate this function.

Cancel quiet function:
• If quiet function has been set, press FUNCTION button 

on the panel to select “Quiet” function option.

• When “Quiet” or “Auto quiet” flashes, if you press 

SWING/ENTER button without pressing   or   button, 
quiet function will be canceled; if you press SWING/
ENTER button after pressing   or 

 

button, quiet 

function will be activated.

 

WIRED CONTROLLER (Continued)

Содержание CAS12HP230V1BC

Страница 1: ...LS CAT NO GREE_CASSETTE B_OWNERS_11102022 Thank you for choosing our product Please read this Owner s Manual carefully before operation and retain it for future reference To download an electric versi...

Страница 2: ...other GREE installed products worldwide has gone into your unit Please read this owner s manual carefully before operation and retain it for future reference TABLE OF CONTENTS Nomenclature 3 Safety Pr...

Страница 3: ...l Electrical Rating 230V 208 230V 1PH 60Hz Style Color Designation Product Type O Outdoor Units C Indoor Cassette D Indoor Slim Duct F Indoor Floor Ceiling Model Type HP Heat Pump Capacity 12 12 000 B...

Страница 4: ...hanced installation reliability or operation NOTE Your actual air conditioning heating system and related devices may differ from the images shown in this manual WARNING This appliance is not intended...

Страница 5: ...g be careful not to splash water on the unit Doing this may cause electric shock or damage to unit Do not use or place any flammable combustible or noxious substance next to the unit In the event of a...

Страница 6: ...ired Controller 6 Remote Controller 7 Big handle 8 Liquid Pipe 9 Gas pipe 10 Drainage pipe 11 Front Board Indoor unit Outdoor unit 2 3 4 7 5 6 1 8 9 10 11 Air inlet Air outlet Fig 1 DISCLAIMER Not all...

Страница 7: ...it It then adjusts airflow and temperature accordingly for ultimate personal comfort ADJUSTABLE AIRFLOW The Cassette B Series system has a four directional airflow for maximum comfort The indoor unit...

Страница 8: ...ections and system parameters are stored in non volatile memory These parameters are retained during a power failure When power is returned the Cassette B Series system will automatically return to th...

Страница 9: ...when I DEMAND function is set Display when WiFi function is set Lock out status display when lock out function is set Display when up and down swing function is set Icon of follower controller it will...

Страница 10: ...er the lock state in which case any other buttons won t respond Repress them for 5s to quit this state Under OFF state the Celsius and Fahrenheit scales can be switched by pressing MODE and for 5s Und...

Страница 11: ...Cooling Dry Fan or Heating mode the temperature setting range is 61 F 86 F 16o C 30o C IntheAutomode thesettingtemperatureisunadjustable 3 4 Fan Setting Under the ON State of the unit each time you p...

Страница 12: ...ion Swing setting is shown as Fia 9 NOTE 1 Use the Swing setting procedure to initiate Sleep Turbo or X fan 2 Oncethesettingiscompleted press SWING ENTER to initiate another setting or it will automat...

Страница 13: ...indoor unit will be automatically evaporated to avoid mildew In the Cooling or Dry mode press FUNCTION till the unit enters the X fan setting interface and then press SWING ENTER to activate When the...

Страница 14: ...Demand setting interface Press SWING ENTER to confirm the setting I Demand off When the I Demand function is activated press FUNCTION to enter the I Demand setting interface After that press SWING ENT...

Страница 15: ...e seconds to go to the commissioning status Under this status adjust the display in the temperature display area to 00 through the button MODE and then adjust the option of the temperature sensor in t...

Страница 16: ...SERIES OWNERS MANUAL INDOOR UNIT 16 OPERATION OF REMOTE CONTROLLER Buttons on remote controller Introduction for icons on display screen Remote lock out DISCLAIMER All functions are not available for...

Страница 17: ...ate in a fan only mode no heating or cooling and all indicators will be off When all indicators are off press FAN button to adjust fan speed Press button to adjust fan blowing angle When selecting HEA...

Страница 18: ...down at maximum angle Select and fan modulation will stop at that fixed position Horizontal louver will stop at the fixed position Select will not modulate but blow at a fixed angle Hold button more...

Страница 19: ...on the remote controller When set the remote controller will send the detected ambient temperature to the controller and the unit will automatically adjust the indoor temperature according to the det...

Страница 20: ...ither Sleep function and 46 F 8 C heating function can t operate at the same time If 46 F 8 C heating function has been set under heat mode pressing the SLEEP button will cancel 46 F 8 C heating funct...

Страница 21: ...e unit is installed in a room where the air is extremely contaminated As a yardstick for yourself consider cleaning the filter once a half year If dirt becomes impossible to clean change the air filte...

Страница 22: ...the HEAT mode In order to prevent cold air from blowing out it may take several minutes before the fan starts This is normal Air conditioner isn t coming on Power failure Wait until power recovery Lo...

Страница 23: ...s clippings and other debris can stick to coil fins and make the unit work up to 15 harder 5 Rearrange the room Furniture that obstructs the airflow needs to be removed or rearranged accordingly 6 Try...

Страница 24: ..._____________________ Serial No ___________________________________ Outdoor Model No _____________________________ Serial No ___________________________________ Owner Name ____________________________...

Страница 25: ...U S CONTACT INFORMATION TRADEWINDS LLC E mail info twciimate com Contractor Support 888 850 7928 I Mon Fri 8 AM 5 PM EST G R E E C O M F O R T C O M...

Отзывы: