8

16.

 A

ppu

yez

 fe

rm

em

ent

 le

 ch

âss

is 

de

fen

êtr

e i

nté

rie

ur

con

tre

 le

 b

oîti

er 

en 

le

fai

san

t g

lis

ser

. A

ssu

rez

-vo

us 

de 

ne 

pas

enl

eve

r l

a b

and

e p

rot

ect

ric

e d

es 

joi

nts

 d

’é-

tan

ché

ité

 d

u r

ail 

et 

des

 ca

nau

x l

até

rau

x d

u

boî

tie

r. L

ors

que

 le

 ca

dre

 d

e p

ann

eau

 es

t

lég

ère

men

t p

lus

 p

etit

 q

ue 

le 

châ

ssi

s d

e

fen

êtr

e i

nté

rie

ur, 

fix

ez 

le 

cad

re 

de 

pan

nea

u

à l

’ai

de 

de 

vis

 n

o 8

 d

e 3

/4 

po 

ou 

de 

vis

 à

file

tag

e a

uto

mat

iqu

e n

o 8

-32

 d

e 3

/4 

po.

Util

ise

z l

es 

tro

us 

par

tie

lle

men

t b

ouc

hés

 d

u

cad

re 

de 

pan

nea

u. 

Per

cez

 d

es 

ava

nt-

tro

us

(ou

 tr

ous

 d

e g

uid

age

) d

e 1

/8 

po 

pou

r l

es 

vis

.

17.

 A

ccr

och

ez 

le 

dis

pos

iti

f d

e s

écu

rit

é

à l

a

bas

e d

e l

’ap

par

eil 

et 

fix

ez-

le 

à l

’av

ant

 d

e l

a

pla

tef

orm

e. 

Util

ise

z u

ne 

vis

 à 

file

tag

e

aut

om

atiq

ue 

no 

8-3

2 d

e 3

/4 

po.

REM

AR

QU

E :

 

Le 

dis

pos

itif

 d

e s

écu

rité

em

pêc

he 

le 

clim

atis

eur

 d

e b

oug

er 

(ve

rs 

l’a

van

t o

u v

ers

 l’

arr

ièr

e) 

lor

squ

’il 

est

 in

sta

llé

.

18.

 In

sér

ez 

la 

ban

de 

d’é

tan

ché

ité

 en

mou

sse

 o

u l

e j

oin

t d

’ét

anc

héi

té 

pou

r c

hâs

-

sis

 

ent

re 

le 

châ

ssi

s v

ert

ica

l e

t l

a v

itr

e,

com

me 

l’in

diq

ue 

l’il

lus

tra

tio

n d

e d

roi

te.

19.

 U

tili

sez

 le

 d

isp

osi

tif

 d

e f

ixa

tio

n p

our

fen

êtr

e

pou

r f

ixe

r l

e c

hâs

sis

 in

tér

ieu

r à

 la

bas

e d

u c

hâs

sis

 ex

tér

ieu

r. U

tili

sez

 u

ne 

vis

no 

8 d

e 3

/4 

po 

ou 

une

 vi

s à

 fi

let

age

aut

om

atiq

ue 

no 

8-3

2 d

e 3

/4 

po 

(pe

rce

z u

n

ava

nt-

tro

u d

e 1

/8 

po)

.

20.

 Po

ur 

rep

lac

er 

le 

pan

nea

u a

van

t

Rac

cor

dez

 d

’ab

ord

 le

s f

ich

es 

de 

con

tac

t e

t

pos

itio

nne

z l

e d

isp

osi

tif 

d’é

cha

ppe

men

t à

tra

ver

s l

e p

ann

eau

 av

ant

, à

 l’

end

roi

t a

ppr

o-

pri

é. 

Pou

sse

z l

égè

rem

ent

 su

r l

e p

ann

eau

ava

nt. 

Il 

dev

rai

t s

’en

cle

nch

er 

au 

boî

tie

r.

Rem

ette

z e

nsu

ite

 le

s v

is 

de 

ret

enu

e e

n

pla

ce.

 N

e p

ous

sez

 p

as 

ou 

ne 

tir

ez 

pas

 su

r

les

 év

ent

s à

 la

mes

 d

u p

ann

eau

 av

ant

.

Aut

res

 m

ont

ant

s d

e f

enê

tre

Afin

 d

’in

sta

lle

r l

e c

lim

atis

eur

 d

ans

 u

ne 

fen

êtr

e o

ù l

e m

on-

tan

t s

upé

rie

ur 

et 

les

 m

ont

ant

s l

até

rau

x n

e c

om

por

ten

t p

as 

de 

bri

de 

ou 

de 

dis

pos

itif

 d

’ar

-

rêt

 en

 b

ois

, l

es 

can

aux

 et

 la

 ca

dre

 p

our

 p

ann

eau

 d

oiv

ent

 êt

re 

fix

és 

à u

ne 

bri

de 

d’a

cco

u-

ple

men

t (

ou 

à u

n a

ngl

e d

ont

 l’

épa

iss

eur

 es

t é

gal

e o

u i

nfé

rie

ure

 à 

1/1

6 p

o), 

laq

uel

le 

est

fix

ée 

aux

 m

ont

ant

s d

e f

enê

tre

 (v

oir

 l’

illu

str

atio

n A

). 

Les

 il

lus

tra

tio

ns 

B e

t C

 re

pré

sen

ten

t

d’a

utr

es 

sol

utio

ns.

 Su

r l

e c

ôté

 d

u c

hâs

sis

 d

e l

’ou

ver

tur

e, 

le 

coi

n d

u c

hâs

sis

 in

tér

ieu

r

dev

ien

t l

a b

rid

e. V

ous

 p

ouv

ez 

ach

ete

r l

a b

agu

ette

 d

’an

gle

 ch

ez 

un 

mar

cha

nd 

loc

al.

App

uye

z fe

r-

mem

ent

 le

châ

ssi

s d

e

fen

êtr

e

int

éri

eur

 co

ntr

e

le 

boî

tie

r e

n le

fai

san

t g

lis

ser

.

Dis

pos

itif

 de

 sé

cur

ité

Joi

nt d

’ét

anc

héi

pou

r c

hâs

sis

Dis

pos

itif

 de

 fix

atio

n

pou

r fe

nêt

re

Dis

pos

itif

 de

 fix

atio

n

pou

r fe

nêt

re

Ajo

ute

z l’

arr

êt e

n

boi

s c

om

me

l’in

diq

ue 

l’il

lus

tra

tio

n

Ajo

ute

z u

n a

ngl

e d

e

cal

ibr

e 1

6 o

u 1

8

À é

gal

ité

Piè

ce 

Piè

ce 

Ins

tal

lez

 le

s d

isp

osi

tifs

 de

 sé

cur

ité

3/4

 po

ou 

1 p

o

3/4

 po

ou 

1 p

o

1 p

o x

 1

 p

o

ou

 3

/4

 p

x 3

/4

 p

o

an

gle

Piè

ce 

8

16. Slide inner window sash firmly

against

side of the cabinet. Make sure not to peel
the seal strips from the window track and
cabinet side channels. If
the panel frame does not fit snugly to the
inner window sash, secure the panel frame
to the sash with #8x3/4-inch screws, or #8-
32x3/4-inch selfthreading screws. Use the
partially plugged holes in the panel frame.
Drill 1/8-inch pilot holes for the screws.

17. Hook the safety bracket over

the base

of the unit and fasten it to the front of the
platform assembly. Use a #8-32x3/4-inch
self-threading screw.

NOTE:

The bracket prevents movement of

the air conditioner (either in or out) after
completing the installation.

18. Stuff the foam seal strip/sash seal

between the vertical sash and the window
glass, as shown right.

19. Use the window locking bracket

to lock

the inner window sash to the base of the
outer window sash. Use one #8x3/4-inch
screw, or #8-32x3/4- inch self-threading
screw. (Drill 1/8-inch pilot hole).

20. To replace the front

First reconnect the coupler plugs, make the
exhaust control positioned through the front
in the proper location. Gently push the front
into position on the cabinet. It should click
into place. Then replace the retaining
screws that holds the panel in place. 

Do not

push or pull the front panel louvers.

Alternate Window Jamb
Applications

To install in windows having no flanges or wood stops on the top and side jambs, the
channels and panel frame must fit against a mating flange (or 1/16-inch max. thick angle)
attached to the window jambs.
Figure A shows this angle installed. Figures B & C show alternate treatments. On the sash
side of the opening, the leading corner of the inner sash becomes the flange. You can
purchase the angle strip locally.

Slide inner

window sash

firmly against

Cabinet.

Safety bracket

Sash seal

Window locking

bracket

Add angle to

wood stop

Add wood

as shown

Add 16- or 18-

gauge angle

Flush

Room 

Room 

Install safety bracket

3/4 po

or 1 po

3/4 po

or 1 po

1 po x 1 po

ou 3/4 po 

x 3/4 po

angle

Room 

Содержание 13-04685

Страница 1: ...uctions thoroughly before using your air conditioner and keep it for future reference 00526 11 10 11 MODELS 13 04685 13 04686 WWW GREE CA St Mathieu de Beloeil Québec Canada 1 866 680 GREE Tous droits réservés Sunrise Tradex Corp 2011 Lisez attenti Room Air Conditioner OPERATING INSTRUCTIONS ...

Страница 2: ... to a gas line If cold water pipe is interrupted by plastic non metallic gaskets or other insulating materials DO NOT use for grounding Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded DO NOT modify power supply cord plug If it does not fit outlet have a proper out let installed by a qualified electrician DO NOT have a fuse in the neutral or g...

Страница 3: ... not available it is the responsibility of the consumer to have a properly grounded 3 prong wall receptacle installed by a qual ified electrician Preparing for Installation AVERTISSEMENT 3 Prong Grounding Type Wall Receptacle 3 Prong Grounding Plug Grounding prong Power Supply Cord 6 feet long Installation Tips For wood frame casement windows It may be necessary to construct a frame using at least...

Страница 4: ...crews for installation IDENTIFY SCREWS BY LENGTH 2 Choose a proper sized window as shown right 15 1 2 inches minimum width 16 1 4 inches maximum width for casement windows 21 1 4 inches minimum height with window panel retainer 20 5 16 inches minimum height window panel retainer removed 39 7 16 inches maximum height NOTE Height measurement must be of a clear open ing above mounting platform In som...

Страница 5: ...than 1 inch from the side window jambs the 8 11 16 inch measurement must be increased accordingly Screen and storm window frames may also require adjustments to the measurement 3 Center platform assembly on the line with inside platform tab pressed against inside edge of window track Using the holes in the platform as a guide mark and drill two 9 64 inch diameter holes Drill holes in either track ...

Страница 6: ...ach it to window jamb Use appropriate length screws Items 9 11 in Preparing For Installation 7 Adjust platform assembly so that outside edge is 3 16 inch lower than inside edge as shown right This ensures proper water drainage from the air conditioner 8 Level platform assembly from side to side Also make sure window track is level Use leveling shims as necessary to ensure unit is level from side t...

Страница 7: ...hook ends of channels face toward back of unit 12 Slide plastic window panel into panel frame with the smooth side to the room Slide panel frame assembly into side chan nels of the AC cabinet Make sure plastic window panel is firmly enclosed on all sides by the retainer grooves 13 Cut side channel seal into 2 equal lengths Remove protective backing and apply it to the rear side of cabinet side cha...

Страница 8: ...ng bracket to lock the inner window sash to the base of the outer window sash Use one 8x3 4 inch screw or 8 32x3 4 inch self threading screw Drill 1 8 inch pilot hole 20 To replace the front First reconnect the coupler plugs make the exhaust control positioned through the front in the proper location Gently push the front into position on the cabinet It should click into place Then replace the ret...

Страница 9: ...uture To avoid crank handle and window clear ance problems the unit can be installed in a stationary sash section However the hori zontal mullion and the 2 glass panels must be removed before installation 1 Attach support brace to platform as shown Use the adjustment bolt and hex flange nut to complete the assembly Choose the slot and adjustment bolt hole locations that will create a 45 degree ang...

Страница 10: ... top of the platform assembly Subtract 20 5 8 inches Mark this measure ment on the plastic window panel along the longer side 8 Clamp the plastic window panel between a board and a work table and cut along the cutting line with a fine tooth saw Remove any burrs with a file 9 Fasten the side channels to the sides of the unit using three screws Item 17 per channel Make sure hook ends of channels fac...

Страница 11: ... metal case gently pull the front out and lift up to release it from the case 4 Then remove the four screws from the front frame to release the control panel box NOTE DO NOT push or pull air direction louvers 13 Place the air conditioner in the window opening as shown to the right It should sit on the platform assembly so that the win dow panel frame and the cabinet side chan nels are against the ...

Страница 12: ...g the following Be sure the electrical service is adequate for the model you have chosen This information can be found on the serial plate which is located on the side of the cabinet and behind the grille If the air conditioner is to be installed in a window you will probably want to clean both sides of the glass first If the window is a triple track type with a screen panel included remove the sc...

Страница 13: ... as the button engages 4 The power supply cord is now supplying electricity to the unit On some products this is also indicated by a light on the plug head NOTES Do not use this device to turn the unit on or off Always make sure the RESET button is pushed in for correct operation The power supply cord must be replaced if it fails to reset when either the TEST button is pushed or it cannot be reset...

Страница 14: ...lay time when using the Timer pad on the unit The Set light will flash while setting 5 Fan Speed Pads Use to set the fan speed to Low Med High or Auto on the unit 6 Mode Pad Use to set the air conditioner to Cool Energy Saver Fan Only Dry or Auto mode 7 Timer Pad Timer ON can be set under off state of unit If timer ON reaches the system will run under previous setting mode The set ting range is 0 ...

Страница 15: ... conditioners with multifunction For some function which the model doesn t have if press the correspon ding button on the remote controller that the unit will keep the original running status 1 ON OFF Press this button to turn on the unit Press this button again to turn off the unit 2 MODE Each time you press the button a mode is selected in a sequence that goes from AUTO COOL SAVE FAN and DRY as ...

Страница 16: ... EXHAUST CONTROL This exhaust control allows the air conditioner to either recirculate inside air CLOSED or exhaust air to the outside OPEN The CLOSED position is used when maximum cooling is desired It may also be used for air recirculation without cooling when the air conditioner is set in any FAN position The OPEN position removes stale air from the room and exhausts it to the outside Fresh air...

Страница 17: ... to the original carton Do not block air flow inside with blinds curtains or furniture or outside with shrubs enclosures or other buildings The capacity of the room air conditioner must fit the room size for efficient and satisfactory operation Install the room air conditioner on the shady side of your home A window that faces north is best because it is shaded most of the day Close the fireplace ...

Страница 18: ...wall outlet Plug Current Device Tripped Press the RESET button House fuse blown or circuit breaker tripped Replace fuse with time delay type or reset circuit breaker Control is OFF Turn Control ON and set to desired setting Room temperature below 60 F 16 C Cooling may not occur until room temperature rises above 60 F 16 C Temperature sensing element touching cold coil located behind air filter Str...

Страница 19: ...N setting Window vibration poor installation Refer to installation instructions or check with installer Improper installation Tilt air conditioner slightly to the out side to allow water drainage Refer to installation instruc tions check with installer Unit removing large quantity of moisture from humid room This is normal during excessively humid days Remote control not located within range Place...

Страница 20: ...fect 2 Damage caused by misuse tampering or failure to follow the operating and maintenance instructions provided in this owner s manual 3 Damage to the finish of the unit enclosure or to other outer features caused by wear 4 Filter 5 Damage caused by repairs or modifications to the air conditioner made by any person not duly authorized by GREE 6 Insurance and freight costs for the warranty servic...