Air-Pro Meter Operation
Refer to Figure 58
The meter disk is driven, top forward, by a chain drive
(not shown) always connected to the section drive shaft.
At non-planting rows, use a blank disk (page 139).
Seed is air-delivered to the inlet above the air release
screen . Seed customarily fills to the top of the screen,
blocking further air flow from the seed delivery system,
until the seed level falls below the screen.
Seed enters the meter at the seed inlet shutter (if
open), and forms a seed pool at the base of the meter.
Seed pool size is controlled by the shutter handle
setting (which is the only user adjustment at the meter).
Initial shutter settings are given in the seed rate charts.
Meter pressurization air enters the meter at , and exits
the meter primarily at the seed pockets in the seed disk.
The pressure differential holds seed in the disk
pockets rising from the seed pool. Excess seed at a
pocket is picked off by the tickler brushes .
The strip and drop brushes block meter pressurization
air. Seeds passing the drop brush are free to fall into
the seed tube, and are detected by the seed sensor .
Meter Operation
1. Install disks for your crop/population range per the
Seed Rate manual and the instructions beginning on
page 81 of this manual.
2. Open shutters at planting rows to the recommended
initial setting (from the Seed Rate charts). At unused
rows, close Y-tube leg (page 103), install a blank
disk (page 139) and close shutter.
3. Set sprocket indexing if staggering a twin-row crop
(see Seed Rate manual for details).
4. Operate the fan at normal field rpm.
5. On the seed monitor, perform a “FILL METER”
operation.
6. With all rows primed, rotate meters one turn to fill
pockets to edge of drop brush.
For hydraulic drive, engage all clutches, and use a
“FILL DISK” seed monitor operation.
For ground drive, either disengage all clutches and
rotate the section drive shafts (top forward) with a
7
/
8
inch (23 mm) wrench, or raise planter, engage
clutches and rotate ground drive tires (top forward).
7. Leave fan running (to keep seed in top pockets).
Reinstall rain covers. Commence planting.
Meter operation is automatic from this point on.
For hydraulic drive planters, an optional Remote Test
Switch is available from DICKEY-john
®
which allows
at-row control of meter rotation for meter fill and seed
pool recovery operations.
See also:
“
Seed Pool Troubleshooting
” on page 90,
“
Seed Pool Recovery
” on page 91,
“
Meter Clean-Out
” on page 103, and
“
Meter Brush Maintenance
” on page 105.
Figure 58
Air-Pro Seed Meter at Row
29825
3
2
1
5
6
4
7
8
9
1
2
3
4
5
6
7
8
9
Содержание Yield-Pro 3PYPA
Страница 188: ...Great Plains 401 647M 2019 06 11 Table of Contents Index 184 3PYPA Table of Contents Index Appendix R Row Pro...
Страница 194: ...Great Plains 401 647M 2019 06 11 Table of Contents Index 190 3PYPA Table of Contents Index...
Страница 195: ...Table of Contents Index Table of Contents Index...
Страница 196: ...Great Plains Mfg 1525 E North St P O Box 5060 Salina KS 67402 Table of Contents Index...