Hydraulic Drive Operation
56
Varying Rates with Pre-set Function
The Precision Population Controller allows you to pre-set
three different rates, and then change rates on-the-go by
toggling from one rate to another rate with the /
arrow
buttons.
To enter the three pre-set rates, press the FUNCTION
button until Pre-set Menu screen appears: Use /
arrow
buttons to toggle from Manual mode to pre-set mode
Refer to Figure 79, Figure 80 and Figure 81
Press Function button to move to the next pre-set
screen, and the Up-Down arrow keys to set the pre-set
rates.
11. When in Pre-Set mode, the main operating screen
shows the pre-set rate currently being applied.
When you are in Pre-set mode, the /
arrow buttons
only toggle between pre-set rates.
Figure 78
Preset Mode
28274
Figure 79
Preset Mode 1
28275
Figure 80
Preset Mode 2
28276
Figure 81
Preset Mode 3
28277
Figure 82
Preset Operating Mode