2019-03-14
196-538M
3N-40P
Appendix
176
Row Spacing Data
The diagrams in this section show useful measures that
vary between machine models, row spacings, and
modified row spacings.
Use this data for calibration (page 42), setting marker
extension (page 21), and shutting off rows for modified
spacings (page 69).
Example Row Spacing
-6475 as “-1630”
Baseline Span: 476.5 in. (1210 cm)
Active Span: 454 in. (1153 cm)
Swath: 484in/40.3 ft.(1229 cm/12.3 m)
Swath-Averaged Row Spacing: 7.56 in. (19.2 cm)
Active Nominal Row Spacing: 30 inch (76.2 cm)
Row Spacing Data Legend
Find the chart for your drill’s row spacing. Row spacings
are identical across 3N-4010P, -4010HDP and -4020P
and -4025P.
,
: The heading and title block identify the drill
opener configuration, default row count, default row
spacing, and whether the diagram applies to a standard
or modified row spacing.
: Span
is the dimension between the center-lines of
the left and right outside row units. If all are active, only a
single “Span” value is given. If some are inactive, a
“Baseline Span” for all rows is given, as well as an
“Active Span” for just the rows in use. You may need this
data for modified row spacings not shown.
: Swath
is the average width of successive planted
passes. Swath is at least one row spacing wider than the
[Active] Span, and is wider on 7.5 in.models, as there is
an extra 2 in.at each wing-center tool bar gap.
: Row Spacing
Shows standard or “Active” row spacing.
: Each illustration shows three drills, their tool bars
represented by the horizontal lines.
: The large top arrow shows drill centerline the
direction of travel. This is always drill centerline, and not
necessarily the center of the presently active row units.
: Solid lines with arrows across the tool bar show
active row units.
: Dashed lines without arrows across the tool bar
show inactive row units.
,
:Marker Extension values are shown separately
for left and right side opposing passes. They may not be
the same, and can be substantially unequal, particularly
for modified spacings.
For setting marker extension, measure from the mark to
the centerline of the outside opener on each side,
whether that opener row is active or not.
Opposing passes are presumed for these extension
values. For concentric passes, only one marker side
is used. Measure from drill centerline to the mark,
and set the extension to the Swath value
for your
configuration.
1
3
4
5
.epsi
100%
Figure 230: -6475 as -1630
Non-standard spacing: 16 Single 30 inch Rows; 32 rows unused
28242
2
6
7
9
8
10
11