22
DETAIL A
TYP (4) PLC'S
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A
A
B
B
C
C
D
D
DWG NO:
REV
SHEET:
OF
DRAWN
CHECKED & APP.
TITLE
DRAWING NOT TO SCALE
PART NUMBER:
QTY PER UNIT:
1
MATERIAL TYPE:
MATERIAL GAUGE:
FINISH:
GREAT LAKES CASE & CABINET CO., INC.
P.O. BOX 551 EDINBORO, PA 16412
PHONE (814) 734-7303 FAX (814) 734-3907
E-MAIL [email protected]
Use of this document is subject to
a confidentiality and nondisclosure
agreement with Great Lakes Case
& Cabinet Co., Inc. (GLCC) and may
not be reproduced, disclosed or
utilized in whole or in part without
prior written authorization from GLCC.
NOTICE:
TOLERANCE UNLESS OTHERWISE NOTED:
A/- 1
.XXXX +/- .010
.XXX +/- .015
.XX +/- .030
.X FOR REF. ONLY
UNLESS OTHERWISE SPECIFIED
ALL DIMENSIONS ARE IN INCHES
DIMENSIONAL LIMITS APPLY
AFTER APPLICATION OF FINISH
INTERPRET DRAWING PER ASME Y14.5M-1994
THIRD ANGLE
PROJECTION
DATE
DATE
1
2
PCS
2/7/2014
I020760-TEST
EST. WEIGHT :
246.81 lbmass
A
REVISION HISTORY
REV
DESCRIPTION
DATE
APPROVED
0
VCM12
12" Vertical
Cable Manager
Detail A
Rack
1/4-20 x 3/4 lg
Hex Bolt
1/4 Flat Washer
1/4 Flat
Washer
1/4 -20
Hex
Flange
Nut
DETAIL A
TYP (4) PLC'S
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A
A
B
B
C
C
D
D
DWG NO:
REV
SHEET:
OF
DRAWN
CHECKED & APP.
TITLE
DRAWING NOT TO SCALE
PART NUMBER:
QTY PER UNIT:
1
MATERIAL TYPE:
MATERIAL GAUGE:
FINISH:
GREAT LAKES CASE & CABINET CO., INC.
P.O. BOX 551 EDINBORO, PA 16412
PHONE (814) 734-7303 FAX (814) 734-3907
E-MAIL [email protected]
Use of this document is subject to
a confidentiality and nondisclosure
agreement with Great Lakes Case
& Cabinet Co., Inc. (GLCC) and may
not be reproduced, disclosed or
utilized in whole or in part without
prior written authorization from GLCC.
NOTICE:
TOLERANCE UNLESS OTHERWISE NOTED:
A/- 1
.XXXX +/- .010
.XXX +/- .015
.XX +/- .030
.X FOR REF. ONLY
UNLESS OTHERWISE SPECIFIED
ALL DIMENSIONS ARE IN INCHES
DIMENSIONAL LIMITS APPLY
AFTER APPLICATION OF FINISH
INTERPRET DRAWING PER ASME Y14.5M-1994
THIRD ANGLE
PROJECTION
DATE
DATE
1
2
PCS
2/7/2014
I020760-TEST
EST. WEIGHT :
246.81 lbmass
A
REVISION HISTORY
REV
DESCRIPTION
DATE
APPROVED
0
VCM12
VSBK9-14
Note: 5" and 8" Vertical
cable managers
(VCM5-FO/VCM8-FO)
can also be installed
between two racks (or
at the end-of-row rack).
Installation instructions
for these parts will
come with the VCM.
Four variable spacer
brackets are required.
A
12" VERTICAL CABLE MANAGER INSTALLED WITH 4 POST RACK
VCM12-FO-ER
Tools: 7/16" socket and wrench
1. Place the cable manger between 2 racks, racks will need spaced
at 14" apart. Attach the manager to the racks (in all 4 corners), as
shown in Detail A.
FINGER TIGHTEN.
2. After cable manager is attached, go back and tighten all
hardware.
3. Two variable spacer brackets (VSBK9-14) must be used to support
the rear of the racks. See page 15 for installation.