Typical Installation
The installations shown in Fig. 2 are only a guide to help
select and install a pump; they are not actual system
designs.
Typical installation includes (not supplied by Graymills):
D
For solenoid operation: a four-way, 5-port, 3-position
solenoid valve with 1/4-in. ports, or two 3–position
3–way valves. Mac series 44 (4–way), or series 35
(3–way). Either way, air pressure should be released if
not cycling.
D
PLC or timer. Consult your local industrial controls
distributor.
For solenoid operation, the pump must exhaust through
the solenoid. Failure to exhaust through solenoid could
cause the diaphragms to fail.
CAUTION
06504
Figure. 2
KEY
A
1/4” DDP pump
B
Bleed-type master air valve
(required for pump)
C
Air line(s)
E
Master air valve (for accessories)
F
Air line filter
G
Muffler
H
Pump air regulator
J
Fluid drain valve
(required on fluid outlet side of pump)
L
Fluid suction line
N
Fluid supply hose
T
Bung adapter
U
4-way solenoid
Y
Ground wire (required)
See page 4 for installation instructions.
C
J
L
N
T
Y
A
U
Air line to Port A
Air line to Port B
Air line to inlet
Internal Air Valve Operated
Remote Solenoid Operated
E
H
B
G
F
Remote Solenoid View
Internal Air Valve View
C
J
N
A
L
L
C