13
12
Eng
lish
Operating elements
Connecting the battery
Attention:
The black bal-
ancer connector cable (-)
must always be connected to
PIN1 (GND), irrespective of
the number of cells incorpo-
rated in the battery pack (1 to
3) and the number of cables
on the balancer connector.
Charger connection
+
_
WARNING: Only 1 to 3S LiPo or LiMn batteries may be
charged with the ULTRA Quick LiPo 15. Never user it to
charge any other types of battery – fire and explosion hazard!
Batteries with integrated charging mechanisms must not be
connected. Charge your batteries on a fireproof surface
only
.
The balancer connector must be connected for every charging
process.
Connect the battery directly to the charger connection or
use a suitable adapter (only use original Graupner charging
cables).
Make sure that the polarity is correct!
Red = (+)
Black = (-)
1
3
4
5
6
7
2
1. Power switch
2. Mains cable, 100 ~ 240 VAC input (for internal power supply unit)
3. Connection for an 11 to 15 VDC external power supply unit or 12 VDC car battery
4. Charging current slide switch
5. Charge status LED
6. JR socket for transmitter/receiver battery
7. Connection for battery charging cable (4-mm sockets)
8. EH balancer connection for Graupner LiPo balancer connector
8