background image

P4 

Normal Mode 
(1) Basic Operation 
- When Power on, the last used memory will be bound to 
Receiver. 
-  In  case  of  No  Receiver  connection,  if  you  press  the 
button of left stick for 1sec, it will search Receiver. 
- if Receiver is not searched, it will be repeated until find 
Receiver,  and  you  can  bind  with  new  Receiver  by 
pressing BIND/LED Switch. 
   
(2) BIND mode 
In case of no having receiver, which is already saved in 

memory,  then  you  can  bind  with  new  receiver  by 
pressing BIND Switch. 

If Receive Signal is normal, RED LED will be turned On. 
In  case  of  Waiting  Receiver  or  Range  warning,  RED 
LED will be slow blinked. 
 
(3) Range Test mode 
Functional  switch:    Press  shortly  button  of  SPEED  + 
SNAP once. 
After  Binding  with  Receiver,  if  you  shortly  press  this 
functional  Switch,  Range  Test  mode  will  operate  for 
90sec. 
While  operating  Range  mode,  if  you  shortly  press  this 
switch, Range test mode will be ended. 
At  Range  mode  operation,  RED  LED  will  blink  quickly 
and make buzzer sound.   
After 90sec, Beep sound will be occurred one time, and 
enter to Main Mode. 
 
(4) Low Battery Voltage warning 
RED LED will do fast blinking. ( RED LED indicate State) 
At  under  3200V,  Warning  will  be  announced  and  at 
3300V, warning will be removed. 
3Cell Alkaline Battery will be used. 
 
Important Point : 
While Binding, Transmitter should always have distance 
from the Receiver. At least 1m should have. 
Otherwise, it might be connected to Return channel, and 

do malfunction. 

 

Program Mode 

(workable only at Binding condition)

 

(1) Condition of Basic Operation 

Enter  to  Program  mode  :  Press  two  Stick  Switch 
simultaneously for 2sec.   
 
Release  Program  mode  :  Press  two  Stick  Switch 
simultaneously for a second. 

 

Indication  of  Program  mode  :    Red  Led  will  be  blinked 
once per a second interval 

 

Program mode : Blink once per a second interval 

 

(2) Saving Data 

50pcs of last used Data could be saved. 

   

  (3) Adjustment of Servo End Position 

In case of Stick Calibration, Default will be 100%. At this 
value, Customer can adjust trim as below way. 
- 100% --> 1100us ~ 1900us 
At Max. or Min. Position of Stick, adjust Trim Switch 
Range of Trim is available 0% ~ 100% ~ 150%. 
If  move  to  100%  position,  High  Beep  sound  will  be 
occurred once. 
 
  - Red Led will be blinked once per a second interval 

 

  Program mode : Blink once per a second interval 
 
(4) Servo Reverse Set 
This is used when change Servo direction. 
All  sticks  are  on  neutral  position,  and  move  the  trim 
switch to Max. or Min. Position. 
If press Power switch with pressed trim switch to Max. or 
Min.  position,  Normal  mode  and  Reverse  mode  will  be 
changed. 
-  Indication  of  Servo  Receiver  mode  :  Red  Led  will  be 
blinked once per a second interval 
- Normal mode : Green LED will be blinked once per a 
second interval. 

   
 
 
 
 
 

Содержание MZ-8

Страница 1: ... 150 not active in autopilot mode as soon as GPS is connected it will be channel 6 coming home function 3D EASY Use the button on top right of image 180 revolution and additional function CH6 1100us 1900us CH6 when AKRO3D is adjusted in the receiver for normal flight mode with GPS Alpha 150 it will be autopilot function 2 4GHz Quad with 6 Axis Gyro You can attach camera and video module by choosin...

Страница 2: ...zzer will ring twice with 1 second intervals 3D function is for 180 degrees flight To operate use same function with Flip 3 Attitude Function When you push Function button one short sound rings This function is attitude control of general quad copters 4 Rate Function When you push Function button two short sound rings You can do rotation and normal flight on 3D flight mode with transmitter Functio...

Страница 3: ...iption Red LED Green LED Buzzer Bind range Bind status No bind blinking 1s low beep 1 Bind Success on low beep 2 RX receive OK on Range Test fast blinking low beep 2 2sec Error Low Voltage fast blinking High beep 4 2sec Sensor Warring High beep 3 2sec Rx Voltage Temp Error fast blinking High beep 2 2sec Receive rate low No RX slow blinking High beep 1 2sec Factory Error Low beep 1 2sec Normal mode...

Страница 4: ...will be used Important Point While Binding Transmitter should always have distance from the Receiver At least 1m should have Otherwise it might be connected to Return channel and do malfunction Program Mode workable only at Binding condition 1 Condition of Basic Operation Enter to Program mode Press two Stick Switch simultaneously for 2sec Release Program mode Press two Stick Switch simultaneously...

Страница 5: ...ice per a second interval Repetition 5times How to do Stick Calibration 1 Enter to Stick Calibration Mode Turn On the Radio in state of pressing left stick switch If enter to Mode RED LED will blink 3 times Stick calibration mode Blink 3 times per a second interval 2 Set Stick Calibration Move all sticks from side to Side and back to middle position After operated last stick hold it to middle posi...

Страница 6: ...ever there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation be...

Отзывы: