background image

1

XGUARD-25

Laser scanner 

for buiLding automation and security

EN

User’s Guide

 

for product version 0600 and more

Содержание XGUARD-25

Страница 1: ...1 XGUARD 25 Laser scanner for building automation and security EN User s Guide for product version 0600 and more...

Страница 2: ...Caution Laser radiation LED flashes quickly LED flashes LED is off Remote control sequence Other use of the device is outside the permitted purpose and can not be guaranteed by the manufacturer The ma...

Страница 3: ...red laser beams The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel Only trained and qualified personnel may install and adjust the sensor Avoid extreme vibra...

Страница 4: ...ggers relay 1 Field 2 only curtain C1 active triggers relay 2 alarm During night time field 2 is active too and triggers relay 2 intrusion alarm protection of works of art WARNING ALARM day and night...

Страница 5: ...e mounting template Make a hole for the cable if possible Pass the cable 10 cm though the cable opening If drilling an opening is not possible use the cable conduits on the back side of the bracket Po...

Страница 6: ...sensor is changed on purpose or by accident No reference point is memorized no alarm in case of interference with sensor position Adjust the lateral position of the detection field Adjust the tilt an...

Страница 7: ...cut out IMPORTANT Test the good functioning of the installation before leaving the premises Stay outside of the detection field to avoid disturbances WIDTH field 2 field 1 HEIGHT no field WIDTH HEIGH...

Страница 8: ...th fields activate curtain only on field 1 activate curtain only on field 2 activate curtain on both fields EX All curtains active on both fields The distances between the curtains depend on the mount...

Страница 9: ...AVING AN ACCESS CODE DELETING AN ACCESS CODE The access code is recommended for sensors installed close to each other After unlocking the red LED flashes and the sensor can be adjusted by remote contr...

Страница 10: ...and connexion Check wiring The red and blue cable have to be connected to the test input or the power supply Check the size of the fields Launch a teach in Step out of the field and or remove the any...

Страница 11: ...er 75 W CLASS 1 wavelength 650 nm max output CW power 3 mW CLASS 3R 10 35 V DC sensor side 5 W 1 8 A max 80 ms 35 V 10 m typ 20 ms max 80 ms output activation delay 2 electronic relays galvanic isolat...

Страница 12: ...that the FAAC XGUARD 25 is in conformity with the basic requirements and the other relevant provi sions of the directives 2006 95 EC 2002 95 EC and 2004 108 EC Angleur August 2013 Pierre Gardier Autho...