5
1
2
5
6
7
8
1
2
3
4
GREEN
BROWN
WHITE
YELLOW
PINK
VIOLET
RED
BLUE
WHITE/RED
WHITE/BLUE
POWER
POWER SUPPLY -
RELAY 1 - FIELD 1
RELAY 2 - FIELD 2
TEST +
TEST -
TEACH-IN
No monitoring*:
connect red and blue wires to power supply (no polarity)
MOUNTING
wIRING
Use the adhesive
mounting template
to position the sensor
correctly. The grey area
indicates the detection
range.
Drill 4 holes as indicated
on the mounting
template. Make a hole
for the cable if possible.
Pass the cable +/- 10 cm
though the cable opening.
If drilling an opening is
not possible, use the cable
conduits on the back side of
the bracket.
Position the bracket
and fasten the 4 screws
firmly.
Open the protection
cover, plug the
connector and position
the cable in the slit.
Close the protection
cover and fasten it firmly.
Turn the sensor until the
two triangles are face
to face.
Position the housing on
the bracket.
*for more info, please contact FAAC
INSTALLATION STEPS
No teach-in via input*:
connect white/red and white/blue wires to ground