background image

- Flap->elev

Press the direction button to select the flap -> elev line and press the ENT button to highlight 

the value. Press the direction button to adjust the desired value then press the ESC button to 

remove the highlight. Press the direction button to select the hyphen then press the ENT button. 

The popup message “push desired switch into position on” appears. Move the switch then the 

corresponding value appears (The flap -> elev mixing is on/off when the switch is moved). Press 

the direction button to select other mixing.

- Flap->aile

Press the direction button to select the flap -> aile line and press the ENT button to highlight 

the value. Press the direction button to adjust the desired value then press the ESC button to 

remove the highlight. Press the direction button to select the hyphen then press the ENT but-

ton. The popup message “push desired switch into position on” appears. Move the switch then 

the corresponding value appears (The flap -> aile mixing is on/off when the switch is moved). 

Press the direction button to select other mixing.

ENT

ESC

TEL

VIW

ENT

ESC

TEL

VIW

ENT

ESC

TEL

VIW

ENT

ESC

TEL

VIW

ENT

ESC

TEL

VIW

ENT

ESC

TEL

VIW

ENT

ESC

TEL

VIW

ENT

ESC

TEL

VIW

ENT

ESC

TEL

VIW

ENT

ESC

TEL

VIW

ENT

ESC

TEL

VIW

ENT

ESC

TEL

VIW

press

press

press

press

press

press

press

press

38

Содержание m-12 HOTT

Страница 1: ...No S1002 mz 12 HoTT USA mz 12 OPERATING INSTRUCTION Prior to use please read this manual thoroughly Keep this manual in a convenient place for quick and easy reference...

Страница 2: ...8P 48 49P 49P 49P 50P 50P 50 51P 51P 51 52P 52P 52 53P 53 54P 54 55P 55P 58P 58P 58P 59 61P 61 64P 64 67P 67P 68 71P 71 72P 72P 72 75P 75 77P 77 78P 9 10P 10P 10 11P 11P 12P 12 13P 13 14P 14 15P 15 16...

Страница 3: ...cted by signal environment and the electronic jamming signals can cause disorientation and loss of control of your aircraft 3 Since models are hazardous when operated and maintained incorrectly instal...

Страница 4: ...PHONE DATA PIN CHARGE SOCKET TX HANDEL THRO TRIM NECKSTRAP LUG S4 SWITCH S2 SWITCH S1 SWITCH POWER SWITCH ELEV TRIM RUDD TRIM ANTENNA RF TRAINER SWITCH DIAL VOLUME S3 SWITCH THRO AILE STICK AILE TRIM...

Страница 5: ...the transmitter 2 Unscrew the six Philips head screws that hold the transmitter s rear cover and remove the rear case 3 Using a Philips screw driver adjust the stick tension screw for the desired cont...

Страница 6: ...ring in the throttle gimbal of mode 1 transmitter Tension spring Centering cam Centering cam 1 3 2 4 5 7 6 8 Unscrew the tension spring control bolt in the elevator gimbal of mode 1 transmitter Assemb...

Страница 7: ...e below picture you can adjust the screw The sticks of mz 12 Europe Version shall be operated by tension Modes According to the below picture with guideline after disabling the other side stick you ca...

Страница 8: ...result During the charging operation the charger s temperature is slightly elevated This is normal The mz 12 is compatible with all current Graupner Aircraft receivers R Series CHARGING BATTERIES Char...

Страница 9: ...s displayed on the screen ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW press press press press 1 Model mem Aircraft and Helicopter The model mem mode...

Страница 10: ...to the bind procedure ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW press press press press press press Model name Wh...

Страница 11: ...ne then press the ENT button to access to the function Press the direction button to highlight the model that you wish to clear then press the ENT button The popup message YES or NO appears on the scr...

Страница 12: ...e ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW press press press press press press press press Copy m...

Страница 13: ...W press press press press With the transmitter and the home screen displayed press the ENT button Press the direc tion button to highlight the m type quick then press the ENT button to access The mode...

Страница 14: ...ight of the motor at C1 value then press the direction button to select the cut off line Press the ENT button to highlight 100 of the cut off value then press the direction button to adjust the value...

Страница 15: ...d to that position ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW press press ENT ESC TEL VIW press press ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW press Tail type Use the Tail...

Страница 16: ...ton again to return to the previous screen NOTE The correct value should be matched each other since the some value is not match to the others refer to the table ENT ESC TEL VIW ENT ESC TEL VIW ENT ES...

Страница 17: ...ine or the quick3 line then press the ENT button to highlight the value Press the direction button to select the desired value take off thermal dist speed acro landing air tor test at quick2 and quick...

Страница 18: ...2flap at the model type Press the ENT button to access the function The cursor is on the FLA value in the normal line then press the ENT and the direction buttons to highlight and adjust the desired...

Страница 19: ...and the user can check the speed quick link is ON ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW press...

Страница 20: ...L VIW ENT ESC TEL VIW ENT ESC TEL VIW press press press press press press press press press press press Aurtorotat You may set the switch to be used as auto rotation If the switch is on throttle chann...

Страница 21: ...at the desired position and press the ENT button then adjusted value is applied The adjusted value is activated when the throttle stick is in that position NOTE the value of 150 is the throttle stick...

Страница 22: ...n value Press the direction to select the desired value rear or front then press the ESC button to remove the highlight Aurtorotat Press the direction button to select the autorotat line then press th...

Страница 23: ...to highlight Press the direction button to select the desired value then press the ENT button to remove the highlight Press the direction button to select the hyphen then press the ENT button The popu...

Страница 24: ...utton to remove the highlight The S2 S6 channels can be program in the same method with the S1 Cent Center Press the direction button to select the cent value in the S1 line then press the ENT button...

Страница 25: ...ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW press press press ENT ESC TEL VIW ENT ESC TEL VIW press pres...

Страница 26: ...channels Here is the example that the NO 3 switch is set Press the direction button to select the trv value then press the ENT button Both of value and value are simultaneously highlighted Press the...

Страница 27: ...VIW press press press press ENT ESC TEL VIW Cont sett Helicopter The basic setting of the Helicopter cont sett is NO 5 gyro NO6 Throttle Lim DV Digital volume Generally this function is seldom used b...

Страница 28: ...e maxi mum control response Negative exponential increase control sensitivity around neutral D R expo Press the direction button to highlight the D R expo then press the ENT button to access the funct...

Страница 29: ...e servo outputs 1 to max 6 If you try to use more than 1 servos at the aileron or the elevator or the rudder the receiver output socket can be assigned as you intend Rx bind The receiver must be bound...

Страница 30: ...ress the ESC button to remove the highlight then press the direction but ton to select the hyphen Press the ENT button then the popup message push desired switch onto position ON appears Move the swit...

Страница 31: ...enter the binding mode Press the ENT button of the transmitter the system will be connect ed within a few seconds and the model name of the receiver is displayed on the screen after completing the bi...

Страница 32: ...ch You can program the travel direction and range of the flap servos Brak aile When the air brake with the value of the motor at C1 being no or no inv is operated both aileron servos is simultaneously...

Страница 33: ...to access the diff aile mixing then press the ENT button again to highlight the value Press the direction button to adjust the desired value then press the ESC button to remove the highlight Press th...

Страница 34: ...ion button to select the ail flaps line and press the ENT button to highlight the value Press the direction button to adjust the desired value then press the ESC button to remove the highlight Press t...

Страница 35: ...the ENT button The popup message push desired switch into position on appears Move the switch then the corresponding value appears The brak elev mixing is on off when the switch is moved Press the dir...

Страница 36: ...ion button to select the brak flap line and press the ENT button to highlight the value Press the direction button to adjust the desired value then press the ESC button to remove the highlight Press t...

Страница 37: ...n the switch is moved Press the direction button to select other mixing Elev aile Press the direction button to select the elec aile line and press the ENT button to highlight the value Press the dire...

Страница 38: ...irection button to select the flap aile line and press the ENT button to highlight the value Press the direction button to adjust the desired value then press the ESC button to remove the highlight Pr...

Страница 39: ...the high perfor mance Gyro Tail lock or might be need to adjust the small value You can adjust the different value for each quick link Rudd thro This function is used to offset to fall down Helicopte...

Страница 40: ...value Press the ESC button to return to the previous screen NOTE The default values of the point 2 and point 4 is remained not to be programmed so the deact is displayed at the value box You may activ...

Страница 41: ...n to the previous screen NOTE The default values of the point 2 and point 4 is remained not to be programmed so the deact is displayed at the value box You may activate and adjust the desired value by...

Страница 42: ...sired value Press the ESC button to return to the previous screen NOTE The default values of the point 2 and point 4 is remained not to be programmed so the deact is displayed at the value box You may...

Страница 43: ...of Helicopter rotation is clockwise rudd thro function is only operated when rudd is moved to the right side and if the direction of Helicopter rotation is unclockwise rudd thro function is only oper...

Страница 44: ...ton to select the swash lim mixing then press the ENT button to access the function off of the swash lim value is highlighted Press the direction button to adjust the desired the gain then press the E...

Страница 45: ...the trv line Press the direction button to adjust the desired value Both values are adjusted simultane ously and appeared in the diagram 9 free mixer Aircraft and Helicopter The free mixer allows to s...

Страница 46: ...TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW press press pres...

Страница 47: ...highlight the ASY from the SYM then press the ENT button to highlight the trv value in the right Move the stick of the master channel then you can select the trv value in the right side or left side P...

Страница 48: ...travel range of the swashplate and prevent from the mechanical interference of the linkage Press the direction button to highlight the swqashp mix then press the ENT button to access the function The...

Страница 49: ...and LiPo are available Batt warning When the transmitter voltage drops below the preset voltage the transmitter beeps the alarm to warn the low battery Touch sense The touch sense is used for adjustin...

Страница 50: ...method is used to access the function and adjust the value with Batt type programming Contrast The same method is used to access the function and adjust the value with Batt type programming ENT ESC TE...

Страница 51: ...ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW press press RF country The same method is used to access the function and adjust the val...

Страница 52: ...s used to access the function and adjust the value with Batt type programming ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TE...

Страница 53: ...button to select the Delay Press the ENT button to highlight the value then press the direction button to adjust the desired val ue Press the ESC button to highlight the STO Move the stick to the desi...

Страница 54: ...the ENT button to select the T Teacher or P Pupil After completing to select the desired mode in all channels press the direction button to select the hyphen Press the ENT button then the popup messag...

Страница 55: ...button to access the information you can check the displayed information 55 ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL...

Страница 56: ...ry sensors This function allows you to get the data information on receiver 16 SETTING DATA VIEW 16 1 RX DATA VIEW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW press Telemetry is us...

Страница 57: ...button to highlight the value and press UP DOWN buttons to set the desired value Press ENT button to remove the highlight 16 2 RX SERVO REVERSE It is used to decide the direction of servo rotation Pr...

Страница 58: ...TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW press press CENTER The value of servo center in the selected channel at OUTPUT CH can be programmed The center value depends on transmitter throttle and trim p...

Страница 59: ...y useful For example 4 aile 4 flap are used in aircraft 1 4 channels can be set to aile and 5 8 chan nels can be set to flap and then other channels can be set to elev or rudd Press the direction butt...

Страница 60: ...efault value HOLD Press UP DOWN button to select the desired value then press ENT button to remove the highlight ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW press p...

Страница 61: ...This function allows you to set the time that failsafe takes to start under failsafe situation Press DOWN button to access to DELAY line then press ENT button to highlight the default value 0 75sec P...

Страница 62: ...NT ESC TEL VIW FAIL SAFE ALL It is used when you change failsafe position value of all channels You need set all channels to FAIL SAFE to use this function Press DOWN button to access to FAIL SAFE ALL...

Страница 63: ...VE CH Slave CH in FREE MIXER can be selected Press DOWN button to access to SLAVE CH line then press ENT button to highlight the default value 00 Press UP DOWN button to select the desired channel the...

Страница 64: ...ove the highlight ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW press ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW press ENT ESC TEL VIW ENT ESC TEL VIW press ENT ESC TEL VIW press S TRAVEL The m...

Страница 65: ...n CURVE 1 CH line then press UP DOWN buttons to select the desired channel The default setup is CH2 AILE CH3 ELEV CH4 RUDD Press ENT button to remove the highlight and press UP DOWN button to access T...

Страница 66: ...power the max min temperature of receiver CH OUT TYPE of receiver Press UP DOWN buttons to select the desired line and press ENT button then the default value is highlighted Press UP DOWN buttons to...

Страница 67: ...TEMP Temperature warning If receiver temperature is out of the preset temperature transmitter repeats a beep warning Press DOWN buttons to access to ALARM TEMP and press ENT button then the default va...

Страница 68: ...s the last channel of receiver and you may change it SUMO Only the selected channel outputs the signal of all channels of receiver In case that 1 receiver is set to SUMO and the other receiver is set...

Страница 69: ...ENT button to access the function Press DOWN button to select one of RECEIVER GENERAL MODULE ELEC TRIC AIR MOD VARIO MODULE GPS ESC and press ENT button to mark the box The marked function is activat...

Страница 70: ...PEAT is highlighted Press UP DOWN buttons to set the desired value and press ENT button to remove the highlight Press the direction button to highlight the hyphen mark then press ENT button The popup...

Страница 71: ...ed as TRIG on off that switch is designated as TRIG on off After all process the next voice function is accessed whenever the switch is on If the switch that has spring such as S2 is designated as TRI...

Страница 72: ...x if you don t want to use voice function for the desired line ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW press ENT ESC TEL VIW press ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW press ENT ESC...

Страница 73: ...the desired optional sensors 20 The Programming Setup For Telemetry Sensors ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW RECEIVER You may program the telemetry voice function of rec...

Страница 74: ...SC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW ENT ESC TEL VIW press press press press press...

Страница 75: ...n is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operat...

Страница 76: ...ffice your household waste disposal service or where you purchased the produce NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15...

Страница 77: ...mz 12...

Отзывы: