1
Dial with tappets
2
Channel 1 LED: lights up if channel is active (CH)
3
Mounting plate
4
Channel 1 manual switch (CH)
5
Channel 2 manual switch (HW)
6
Cover
7
Channel 2 LED: lights up if channel is active (HW)
The “thermio™ eco B2” timer is an analogue two-channel synchronous timer that switches connected
loads on and off at defined times.
The “thermio™ eco B2” timer is used to regulate two heating circuits. Hot water or heating circuits can
be connected and regulated independently of each other in the OFF and CONST. operating mode. In
TIME operating mode, the two heating circuits are regulated together, according to the setting of the ON
or OFF tappets. Individual regulation of, for example, central heating and hot water is implemented using
two independent switching outputs.
Abbreviations
•
CH = Central Heating
•
HW = Hot Water
8
Содержание thermio eco b1
Страница 1: ...thermio eco B1 and B2 EN Operating manual...
Страница 5: ...Overview thermio eco B1 and mounting plate Fig 1 Front and side view EN 5...
Страница 7: ...thermio eco B2 and mounting plate Fig 2 Front and side view EN 7...
Страница 19: ...The screw in the mounting plate is captive in other words you can loosen it but you cannot remove it EN 19...
Страница 35: ...Fig 12 Saunier Duval SD 625M EN 35...
Страница 36: ...ElM Leblanc GVM 420 Fig 13 ElM Leblanc GVM 420 36...
Страница 41: ...Fig 15 Gravity heating with room thermostat EN 41...
Страница 42: ...Fig 16 Gravity heating with valves Only valves with switch over limit switches are suitable 42...
Страница 43: ...Fig 17 Pump controlled central heating systems with two way spring loaded check valves EN 43...
Страница 47: ...Operation Setting the time Personnel User Fig 19 Setting the time EN 47...
Страница 54: ...54...
Страница 55: ...EN 55...