39
NOTES:
1. All tests are made with wires in
place on their respective
switches.
2. Problem is in the 'HOLD' circuit
of the fuel solenoid.
3. Relay 'A' is the relay with 1
yellow, 1 black, and 2 red
wires.
MODEL 718D and 721D
(Kubota diesel engines)
ENGINE STARTS, BUT DIES
WHEN KEY SWITCH IS RELEASED
Figure 37
IN RUN POSITION
1
1730
YE
2
4
HO
LD
19
50
AC
-
+
3
CO
M
M
RELAY A
P
U
LL
TO SAFETY
SWITCHES
W H
G R
B K
STARTER
Ba ttery Ca ble
FUEL
SOLENOID
FUEL
SOLENOID
MODULE
IGNITION
FUSE
MAIN
FUSE
KEY
SWITCH
R D
R D
R D
R D
R D
B K
B K
B K
B K
IN-LINE
FUSEHOLDER
Yes
No
No
Yes
continued
A
Does voltage
appear from
'HOLD' wire of
fuel solenoid to
ground?
Check fuel
solenoid plug
connection
Does voltage
appear from
terminal 4 of fuel
solenoid module
to ground?
Replace fuel
solenoid module.
Problem is fuel
solenoid or
binding linkage.
Solenoid 'HOLD'
to 'COMM' wires
should test
approximately
14 to 16 ohms
resistance.