Sonata Series — Planning and Installation Manual
59
Section
4
Troubleshooting
The Sonata AES-to-MADI converter has an integrated alarm system that
will alert the user of a power supply problem. There are three LEDs on the
front panel as well as an SMPTE standard alarm connector on the rear panel
for remote alarm monitoring. Internal regulated voltages are measured
along with the presence of each of the power supply voltages. Any internal
voltage error will turn the Alarm LED red.
LEDs
The Sonata converter power supplies are fully redundant and the unit can
operate using either supply. See
for LED details.
Front Panel
Table 20. Front Panel LEDs
Signal Present LEDs
The AES-to-MADI and MADI-to-AES signal present LEDs will be off
unless a valid AES signal is being decoded, at which time the LED will then
be green. The Analog-to-MADI and MADI-to-Analog will be green when a
signal is present between -50 dB and -4 dB full-scale. The LED's will turn
red between -4 dBFS and 0 dBFS.
Display
Meaning
Power LEDs
Alarm
Green
Power on, OK
Red
Power on, at least one power fault A or B
Off
System is not powered
A
Green
Supply A on and OK
Red
Supply A bad or not plugged in
B
Green
Supply B on, and OK
Red
Supply B bad or not plugged in
Содержание Sonata Series
Страница 1: ...Sonata Series MADI AES Analog Audio Converters Planning and Installation Manual 071860902 MAY 2009 ...
Страница 3: ...Sonata Series MADI AES Analog Audio Converters Planning and Installation Manual 071860902 MAY 2009 ...
Страница 8: ...8 Sonata Series Planning and Installation Manual Preface ...
Страница 24: ...24 Sonata Series Planning and Installation Manual Regulatory Notices ...
Страница 50: ...50 Sonata Series Planning and Installation Manual Section 2 Planning Guide ...
Страница 57: ...Sonata Series Planning and Installation Manual 57 DIP Switches ...
Страница 66: ...66 Sonata Series Planning and Installation Manual Appendix A Specifications ...