Performer-HD Instruction Manual
2-5
Dip Switch Configurations
Performer-HD ASCII
provides an example of a Performer ASCII string used to control
a Performer-HD via a PC. The command string will switch video input
number 5 on all levels of the Performer-HD (video, audio1, and audio2).
■
Preset string = ^M007D000501
■
Take string = ^M0003T01
Table 2-1. Performer-HD ASCII Command String
ASCII
Description
Preset String
Byte 1
^M
carriage return
Byte 2
00
Performer address
Byte 3
07
number of data string characters
CMD
D
data preset, source to destination
Byte 4
00
level, 00 = all levels
Byte 5
05
input selection
Byte 6
01
output selection
Take Strings
Byte 1
^M
carriage return
Byte 2
00
Performer address
Byte 3
03
number of data string characters
CMD
T
take the specified destination
Byte 4
01
output selection