3-12
Performer-HD Instruction Manual
Section 3 — Operation and Maintenance
Data
indicates the data to be inserted following a command character,
indicates the command string elements.
indicates the level settings set by
<Lvl Hi>
and
<Lvl Lo>
.
Table 3-4. Data Types
Data Type
Command String Elements
<Sources>
<Lvl Hi> <Lvl Lo> <Src Hi> <Src Lo> <Dest Hi><Dest Lo>
<Dest>
<Dest Hi> <Dest Lo>
<Status>
<PC> <Lvl Hi> <Lvl Lo> <Src Hi> <Src Lo><Dest Hi> <Dest Lo>
Table 3-5. Command String Elements
Element
Description
<PC>
P(50H) if protect active, C(43H) if protect clear
<Lvl Hi>
0-F, high nibble of level
<Lvl Lo>
0-F, low nibble of level
<Src Hi>
0-F, high nibble of source
<Src Lo>
0-F, low nibble of source
<Dest Hi>
0-F, high nibble of destination
<Dest Lo>
0-F, low nibble of destination
Table 3-6. Level Settings
LvL Hi
LvL Lo
Result
0
0
All Levels (AFV)
0
1
Video
0
2
Audio 1
0
3
Audio 2