8

Kaleido-X16 Installation

Power Supplies

PSU slot locations

Two PSUs installed in a frame; front cover removed

Removing a Power Supply

To remove a power supply

1 Open the front cover of the frame and locate the power supply (PSU) you would like to 

remove (either the left or the right side).

2 Pull on the handle on the right side of the PSU and pull the PSU out of the frame.

Installing a Power Supply

To install a power supply

1 Position the power supply (PSU) in front of an empty power supply slot in front of the 

frame, with the connector end towards the frame and the PSU handle on the right side.

2 Slide the PSU into the empty slot, moving it gently until it contacts the sockets at the 

rear of the slot.

3 Push firmly but gently on the PSU faceplate until the PSU’s connectors have mated with 

the frame's sockets, and the PSU will go in no further.

Powering up the Kaleido-X16

Separate AC power sockets serve the two power supplies. On the rear of the frame, connect 
both power sockets of the Kaleido-X16 to an appropriate power source using the supplied 
power cords.

As seen from the rear of the frame:

• The left power socket is for PSU B.

• The right power socket is for PSU A.

Slot A

Slot B

PSU A

 removed from 

Slot A

Содержание Kaleido-X16

Страница 1: ...Hardware Description Installation Manual M869 9902 114 17 December 2014 ...

Страница 2: ...eido multiviewers to use their product manuals for their own internal business use Manuals for Grass Valley products may not be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying and recording for any purpose unless specifically authorized in writing by Grass Valley A Grass Valley manual may have been revised to reflect changes made to the product...

Страница 3: ...ground prior to making any other equipment connections Identifies an external protective grounding terminal which may be connected to earth ground as a supplement to an internal grounding terminal Indicates that static sensitive components are present which may be damaged by electrostatic discharge Use anti static procedures equipment and surfaces during servicing Indicates that the equipment has ...

Страница 4: ...uid or aerosol cleaners use only a damp cloth Dangerous voltages may exist at several points in this equipment To avoid injury do not touch exposed connections and components while power is on High leakage current may be present Earth connection of product is essential before connecting power Prior to servicing remove jewelry such as rings watches and other metallic objects To avoid fire hazard us...

Страница 5: ...his equipment Electrostatic Discharge ESD Protection Electrostatic discharge occurs when electronic components are improperly handled and can result in intermittent failure or complete damage adversely affecting an electrical circuit When you remove and replace any card from a frame always follow ESD prevention procedures Ensure that the frame is electrically connected to earth ground through the ...

Страница 6: ...s le texte doit être remplacé par un fusible du même calibre Identifie une borne de mise à la terre de protection Il faut relier cette borne à la terre avant d effectuer toute autre connexion à l équipement Identifie une borne de mise à la terre externe qui peut être connectée en tant que borne de mise à la terre supplémentaire Signale la présence de composants sensibles à l électricité statique e...

Страница 7: ...e pas endommager les connecteurs Coupez l alimentation avant de nettoyer l équipement Ne pas utiliser de nettoyants liquides ou en aérosol Utilisez uniquement un chiffon humide Des tensions dangereuses peuvent exister en plusieurs points dans cet équipement Pour éviter toute blessure ne touchez pas aux connexions ou aux composants exposés lorsque l appareil est sous tension Avant de procéder à tou...

Страница 8: ...arations autres que celles qui sont décrites dans le présent manuel sauf si vous êtes qualifié pour le faire Confiez les réparations à un technicien qualifié La maintenance doit se réaliser dans un milieu libre d électricité statique L appareil peut comporter plus d un cordon d alimentation Afin de prévenir les chocs électriques débrancher tous les cordons d alimentation avant toute opération d en...

Страница 9: ...omplies with the requirements of the following standards for safety of information technology equipment CSA C22 2 No 60950 1 07 2nd Edition UL 60950 1 2nd Edition EN 60950 1 2006 ITE IEC 60950 1 2005 2nd Edition The power cords supplied with this equipment meet the appropriate national standards for the country of destination Electromagnetic Compatibility This equipment has been tested for verific...

Страница 10: ...3 3 Limitation of voltage fluctuations and flicker EN 61000 4 2 Electrostatic discharge immunity EN 61000 4 3 Radiated radio frequency electromagnetic field immunity EN 61000 4 4 Electrical fast transient immunity EN 61000 4 5 Surge transient immunity EN 61000 4 6 Conducted disturbances immunity EN 61000 4 8 Power frequency magnetic field immunity EN 61000 4 11 Voltage dips short interruptions and...

Страница 11: ...nical Installation 4 Frame and Electrical Installation 5 CompactFlash 11 Signalling 11 Maintenance 21 2 Specifications 23 Inputs 23 Outputs 25 Audio I O 28 Control 28 Frame 29 Appendix Disposal and Recycling Information 31 Contact Us 33 Table of Contents ...

Страница 12: ......

Страница 13: ...fective multi image processor It can accommodate smaller systems or scale up to production systems where smaller building blocks with fewer input counts per display are desirable Each chassis can display up to 16 auto sensing HD SD or Analog inputs that can be displayed across two high resolution outputs at multiple sizes Features Small form factor 1RU Expandable Expandable multi room architecture...

Страница 14: ...ts inputs and outputs Examples of the various external devices that connect to the Kaleido X16 are also shown Kaleido X16 as a router The Kaleido X16 can behave as a router with 16 input channels as sources and the two RT OUT outputs as destinations Superior display Highest quality multi image output without compression with superior on screen graphics for the most critical live monitoring applica...

Страница 15: ...n addition to the difference in the number of output heads the Audio I O TBA pinout is different between the two models see Audio I O TBA on page 14 for details Kaleido X16 S There is one head Head 1 on the single head Kaleido X16 Kaleido X16 S The Input and Output connections are as follows The rear connector panel for this model is displayed below In addition to the difference in the number of h...

Страница 16: ...tiviewer Mounting the Kaleido X16 in a Rack To mount the Kaleido X16 in a standard 19 inch rack 1 Install both support brackets at the back of the rack by using suitable screws and washers not included so that the bottom of the Kaleido X16 frame will be supported by the brackets Part number Adapter cabling RS 422 pinout at the DE 9P connector 1737 3000 102 Straight Controller SMPTE master mode 179...

Страница 17: ...ash card USB connector and basic LEDs The Kaleido X16 frame incorporates the following key elements A rack mountable mechanical framework for mounting into a 19 inch EIA rack A removable door to cover and protect the front of the frame An optional redundant power supply Ventilation Front view of the Kaleido X16 frame PSUs installed front cover removed IMPORTANT Mobile Installation Ifyou are deploy...

Страница 18: ... locked N A Inputs are unlocked or no input ERROR ON SIGNAL N A N A Front cover is closed DVI Inputs Inputs are locked N A Inputs are unlocked or no input ERROR ON SIGNAL N A N A Front cover is closed LTC LTC valid N A No signal N A N A N A Front cover is closed Ref Input Input is locked N A Input is unlocked or no input ERROR ON SIGNAL N A N A Front cover is closed SDTI Inputs are locked N A Inpu...

Страница 19: ...to as PSU A and the PSU on the right side is PSU B Access the power supplies by removing the front cover of the frame Viewed from the front of the frame the PSUs are located on the left hand and right hand sides of the frame IMPORTANT When measuring the ambient room temperature take your readings from directly in front of the Kaleido X16 frame IMPORTANT If your frame has only one PSU it must be in...

Страница 20: ... of the frame with the connector end towards the frame and the PSU handle on the right side 2 Slide the PSU into the empty slot moving it gently until it contacts the sockets at the rear of the slot 3 Push firmly but gently on the PSU faceplate until the PSU s connectors have mated with the frame s sockets and the PSU will go in no further Powering up the Kaleido X16 Separate AC power sockets serv...

Страница 21: ... within the frame IMPORTANT A Kaleido X16 multiviewer can draw 4 0 amps of current Ensure that the circuit to which the frame is connected can handle that load and that of any other connected devices If you only have one PSU make sure you plug your power cable into the power connector on the right side of the rear connector panel as you face the rear of the frame This should be on the same side of...

Страница 22: ... front Each PSU draws air through the frame s front grille through the PSU then out to the closest rear fan to be exhausted out the side of the frame see diagrams above and below Air Filter Cooling air drawn into the Kaleido X16 frame by the ventilating fans passes through a filter located behind a grille in the front cover of the frame For more information about cleaning the air filter see Cleani...

Страница 23: ... on the two models see Kaleido X16 D on page 3 and Kaleido X16 S on page 3 Connector label Connector type Function DVI IN1 2 DVI DVI input signal that can be used as a background in the monitor wall display in place of the internally generated background INPUTS 1 16 BNC HD SD SDI or composite video inputs 1 to 16 MV OUT 1 2 HDMI HDMI output including embedded audio for each head SDI OUT 1 2 BNC Se...

Страница 24: ...ion details AUDIO I O HD 26 female Supports two AES3 audio outputs or two analog audio outputs for monitoring SDTI BNC Multiplexed audio from an external audio box Audio Bridge Terminal ETHERNET RJ 45 100 Base T Ethernet connection USB USB Connect a mouse keyboard or USB flash memory for software upgrade or data backup Note There are three USB ports one on the front of the frame behind the front c...

Страница 25: ... The external reference REF input signal allows the Kaleido X16 to genlock to the local plant Note To use an HDMI output connection as a DVI output use an HDMI cable with an HDMI to DVI adapter at one end Alternatively use an HDMI to DVI cable IMPORTANT Audio monitoring at the HD SDI outputs is supported on recent hardware only Support for audio monitoring at the HD SDI outputs requires version 5 ...

Страница 26: ...hrough its HD 26 connector The supported formats are AES3 digital audio and analog audio In addition the Kaleido X16 supports audio monitoring through the SDTI input port from an audio bridge terminal ABT Audio I O TBA To facilitate cabling through the HD 26 connector a terminal block adapter TBA is available separately order code NSH26M Audio I O Terminal Block Adapter installed in rear connector...

Страница 27: ... the Kaleido X User s Manual calibrating audio monitoring color see Calibrating the Audio Monitoring Color in the Calibrating the Kaleido X chapter of the Kaleido X User s Manual Bottom row Center row Top row 19 GND 10 AES Out 1 1 AES Out 1 20 GND 11 AES Out 2 2 AES Out 2 21 GND 12 GND 3 GND 22 GND 13 Analog Left Out 1 4 Analog Left Out 1 23 GND 14 Analog Right Out 1 5 Analog Right Out 1 24 GND 15...

Страница 28: ...s a DB 44 female on the connector panel male on the cable There are 44 GPI connector pins 40 not including GND whose functions are as follows 4 Ground GND pins 32 GPI Input pins 4 GPI Output Emitter pins designated in the table below as N 4 GPI Output Collector pins designated in the table below as P The exact pinout for the GPI connector is as follows Bottom row Middle row Top row Pin Description...

Страница 29: ...PI Input 28 37 GPI Input 29 22 GPI Input 30 7 GPI Input 31 38 GPI Input 20 23 GPI Input 32 8 GPI Input 18 39 GPI Input 16 24 GPI Input 19 9 GPI Input 15 40 GPI Input 14 25 GPI Input 17 10 GPI Input 12 41 GND 26 GPI Input 13 11 GPI Input 10 42 GPI Input 9 27 GPI Input 11 12 GPI Input 7 43 GPI Input 6 28 GPI Input 8 13 GPI Input 4 44 GPI Input 3 29 GPI Input 5 14 GPI Input 1 30 GPI Input 2 15 GND CA...

Страница 30: ...positive and negative terminal connections Each column on the terminal block has 6 positive and 6 negative terminal connections that correspond to each pin position Negative pins labelled with an N on the Terminal Block Adapter are not used as connections Positive pins labelled with a P and Ground pins labelled with a GND correspond to GPI input connections GPI Terminal Block Adapter installed in ...

Страница 31: ... Calibrating GPI Lines in the Calibrating the Kaleido X chapter of the Kaleido X User s Manual Ethernet The Kaleido X16 supports one Ethernet connection through an RJ 45 connector see Ethernet on page 29 for specification details USB The Kaleido X16 has three USB 1 0 connectors see USB on page 29 for specification details Connect a mouse keyboard or USB flash memory for a software upgrade or data ...

Страница 32: ...ication e g most routers Ross Synergy switchers Nevion ETH CON Note The Kaleido X16 s two RS 422 ports each have an RJ 45 connector in order to preserve space on a busy panel The RS 422 interface specifies a DE 9 connector so if you are using this interface you will require a DE 9 to RJ 45 adapter Grass Valley supplies two adapter models correctly wired for this application a straight adapter part...

Страница 33: ...over from the frame 2 Place the cover flat on a work surface with the inside facing up 3 Using a vacuum cleaner with a brush nozzle to prevent scratching vacuum the dust from the inner side of the cover 4 Turn the cover over and vacuum the outer side of it 5 Reinstall the cover onto the frame Note The two RS 422 ports on the Kaleido X16 side have no ground pin Using the appropriate DE 9S to RJ 45 ...

Страница 34: ...ctive Power Supply In the event of a power supply failure the unit will switch to the redundant power supply for its power source If a PSU s LED is not green you must replace the unit For more information about removing and reinstalling a power supply see Power Supplies on page 7 ...

Страница 35: ...the video inputs are genlocked and two or three fields if the video inputs are not genlocked Signal inputs require BNC connectors Composite Inputs Signal NTSC SMPTE ST 170 NTSC J PAL BGDHI PAL N PAL M SECAM Return loss 30 dB up to 5 75 MHz Quantization 8 bits SD SDI Inputs Signal 4 2 2 SMPTE ST 259 C 270 Mbps Formats 525 and 625 Audio SMPTE ST 274 1994 Cable length 225 m 738 ft Belden 1694A Return...

Страница 36: ...59 94 on the monitor wall and in XAdmin s Status and Options page Audio SMPTE ST 299 1 Return loss 15 dB up to 1 485 GHz Jitter 0 2 UI Cable length 100 m 328 ft Belden 1694A 3Gbps Inputs Signal 4 2 2 SMPTE ST 424 2006 2 97 1 001 Gbps Formats 1080p50 1080p59 94 Audio SMPTE ST 299 1 Return loss 15 dB up to 1 485 GHz 10dB up to 2 97GHzß Jitter 0 2 UI Cable length 100 m 328 ft Belden 1694A Graphics co...

Страница 37: ...he selected output resolution on your display monitor s tolerance and on the quality of the HDMI cable itself a longer cable could be used as long as the signal integrity is maintained between the multiviewer and the display monitor For example with a 1080p output resolution longer high speed HDMI cables may require an HDMI booster Connector HDMI Supported cable types HDMI to HDMI or HDMI to DVI D...

Страница 38: ...0i59 94 1080PsF23 98 1080PsF24 1080PsF25 1080p23 98ß 1080p24 1080p29 97 Audio SMPTE ST 299 1 limited to one pair embedded on group 1 pair 1 Cable length 100 m 328 ft Belden 1694A Jitter 0 2 UI p p Connectors BNC 3G SDI Monitoring Outputs Signal 4 2 2 SMPTE ST 424 2006 2 97 Gbps 2 97 1 001 Gbps Formats Level A only 1080p50 1080p59 94 Audio SMPTE ST 299 1 limited to one pair embedded on group 1 pair...

Страница 39: ...tor type BNC HD SDI Router Outputs Signal 4 2 2 SMPTE ST 292 C 1 5 Gbps Formats 720p59 94 1080i50 1080i59 94 1080PsF23 98 1080PsF24 1080PsF25 1080PsF29 97 1080p23 98 1080p24 1080p29 97 Cable length 100 m 328 ft Belden 1694A Return loss 15 dB up to 1 5 GHz Additive jitter 0 2 UI p p wideband Connector BNC 3G SDI Router Outputs Signal 4 2 2 SMPTE ST 424 2006 2 97 Gbps 2 97 1 001 Gbps Formats 1080p50...

Страница 40: ...ion SDTI Audio Input Signal SMPTE ST 305 up to 128 channels 64 AES Cable length 250 m 820 ft Belden 1694A Connector BNC Analog Audio Output Signal Balanced analog audio Level MAX 24 dBu Quantization 20 24 bits Impedance 600 THD N 80 dB SNR 92 dB Connector HD 26 AES Outputs Signal Balanced digital audio Format AES3 Level 4 V p p Impedance 110 Connector HD 26 Ω Ω Time Code Inputs LTC Signal SMPTE ST...

Страница 41: ...Volts max Connector DB 44 GPI OUTPUT up to 4 Description Contact closure to GND Signal Open collector 5 to 12 VDC Contact closure current 50 mA max Reverse voltage 15 Volts max Reverse current 50 mA max V out low 0 6 Volts at 1 5mA Connector DB 44 Ethernet Signal 10 100 BASE T IEEE 802 3 Connector RJ 45 RS 422 Signal RS 422 SMPTE ST 207 EBU 3245 Connector RJ 45 USB Signal USB Version 1 0 Connector...

Страница 42: ... mounting flange for standard 19 inch rack D with cover and connectors 641 mm 25 25 in D without cover and connectors 591 mm 23 25 in Full spec temp range 0 40 C ambient Storage humidity 90 RH non condensing Functional humidity 65 RH non condensing Weight 2 PSUs 10 5 kg 23 lbs Weight 1 PSU 9 5 kg 21 lbs ...

Страница 43: ...local environmental laws and guidelines WARNING Be careful not to short circuit the batteries by adhering to the appropriate safe handling practices Do not dispose of batteries in a fire as they may explode Batteries may explode if damaged or overheated Do not dispose of batteries as household waste Do not dismantle open or shred batteries Keep batteries out of the reach of children The electrolyt...

Страница 44: ...s mechanically or electrically abused The most likely risk is acute exposure when a cell vents In the event of a battery leak do not allow battery liquid to come in contact with skin or eyes Seek medical help immediately in case of ingestion inhalation skin or eye contact or suspected exposure to the contents of an opened battery WARNING continued ...

Страница 45: ... number for the support center nearest you please consult the Product Support section of Grass Valley s Web site at http www grassvalley com support contact An online form for e mail contact is also available from the Web site Corporate Head Office Grass Valley 3499 Douglas B Floreani St Laurent Quebec H4S 2C6 Canada Telephone 1 514 333 1772 Fax 1 514 333 9828 www grassvalley com ...

Отзывы: