K2 Storage System Instruction Manual
July 3, 2007
Chapter 3 Installing the Level 2R Storage System
Make a direct connection between the serial ports of the two servers.
Take care to use the proper serial cable to interconnect redundant K2 Media
Servers that take the role of file system/database servers. This cable supports the
heartbeat mechanism whereby the servers monitor each other’s health. It is a 9
pin serial cable, but it is not a standard RS-232 null modem cable. The heartbeat
cable is supplied with your system (Grass Valley part number 174-8137-00) and
has a pin configuration as follows:
1 – 4
2 – 3
3 – 2
4 – 1&6
5 – 5
6 – 4
7 – 8
8 – 7
9 – No Connect
• Assign a control network IP address to GigE port 1. Use standard Windows
procedures. Refer to
“Networking tips” on page 56
.
• Change the hostname. Use standard Windows procedures.
• Configure SNMP properties so the trap destination points to the NetCentral server
PC. Use standard Windows procedures. If you are not using the SNMP community
name “public”, configure the community name and set permissions to RW. Also
make sure that the Authentication trap is enabled.
“K2 Media Server description” on page 287
Setting up the L2 RAID chassis
Do the following to prepare the L2 RAID storage devices:
• Install the chassis in its permanent location. Refer to the L2 RAID Instruction
Manual for rack mount instructions.
•
“Assign Fibre Channel address ID” on page 85
•
“Connect the L2 RAID chassis” on page 85
•
“Assign chassis address on Expansion chassis” on page 86
.
•
“Power on the L2 RAID chassis” on page 88
In addition, you will configure network settings, SNMP settings, and bind LUNs.
These tasks are part of the K2 System Configuration application and Storage Utility
procedures later in this chapter. The process of binding LUNs can take a significant
amount of time—as much as eight hours—so you might want to put priority on the
tasks necessary to start the LUN binding process, then catch up with other tasks while
the LUNs are binding.
“K2 Level 2 RAID storage description” on page 290
.
Содержание K2 BASECAMP EXPRESS
Страница 1: ...K2 STORAGE SYSTEM Instruction Manual SOFTWARE VERSION 3 2 071 8461 02 JULY 2007 ...
Страница 8: ...8 K2 Storage System Instruction Manual July 3 2007 Contents ...
Страница 14: ...14 K2 Storage System Instruction Manual July 3 2007 Safety Summaries ...
Страница 20: ...20 K2 Storage System Instruction Manual July 3 2007 Finding Information ...
Страница 24: ...24 K2 Storage System Instruction Manual July 3 2007 Chapter 1 Product Description ...
Страница 67: ...July 3 2007 K2 Storage System Instruction Manual 67 ...
Страница 68: ...68 K2 Storage System Instruction Manual July 3 2007 Chapter 2 Installing the Level 2 Storage System ...
Страница 172: ...172 K2 Storage System Instruction Manual July 3 2007 Chapter 4 Installing the Level 3 Storage System ...
Страница 236: ...236 K2 Storage System Instruction Manual July 3 2007 Chapter 5 Installing the Level 3R Storage System ...
Страница 282: ...282 K2 Storage System Instruction Manual July 3 2007 Chapter 6 Installing the Nearline Storage System ...
Страница 294: ...294 K2 Storage System Instruction Manual July 3 2007 Chapter 7 Description of K2 Storage Devices ...
Страница 300: ...300 K2 Storage System Instruction Manual July 3 2007 Chapter 8 Overview of K2 Storage Tools ...
Страница 390: ...390 K2 Storage System Instruction Manual July 3 2007 Chapter 11 Administering and maintaining the K2 Storage System ...