![GRASS VALLEY K2 BASECAMP EXPRESS Скачать руководство пользователя страница 384](http://html.mh-extra.com/html/grass-valley/k2-basecamp-express/k2-basecamp-express_instruction-manual_2257918384.webp)
384
K2 Storage System Instruction Manual
July 3, 2007
Chapter 11 Administering and maintaining the K2 Storage System
When the RAID controller detects that the disk module has failed, it automatically
disables the disk module. This is reported in Storage Utility, and you should verify
that the disk module is disabled before removing it.
In some cases you might suspect that the disk module is going bad, but the controller
has not yet detected a failure and has therefore not yet disabled the drive. In this case
you should manually disable the disk module before you remove it. This avoids
momentary interruptions in signal output that can occur. The disabled state is
persistent and the disk remains disabled even if the RAID chassis is restarted. After
replacing the disabled disk module, the disk rebuild process starts automatically,
which also enables the disk module.
To replace a disk module, do the following:
1. Open Storage Utility.
2. Expand the tree view to display bound disks.
NOTE: Disks modules may not be visible in the tree view if they are part of a newly
bound LUN. You must restart your RAID chassis and the K2 Media Server to allow
the drive modules to be seen in Storage Utility.
3. Identify the disk in question. Refer to
“Identifying disks” on page 377
.
4. Select the disk module icon and check its status, then proceed as follows:
• If the disk module reports as disabled, proceed to the next step in this procedure.
• If the disk module reports as online, right-click the disk module and select
Advanced | Disable Drive
, then click
OK
to continue. A message “…operation
succeeded…” appears. The disk is disabled, as reported by the disk fault LED.
NOTE: If you accidentally disable the wrong disk module, you can enable it again
by removing it and then replacing it in the chassis.
5. Remove and replace the disk module.
Refer to procedures in the Instruction Manual for your level of RAID storage
chassis.
On inserting the replacement disk module, the RAID controller automatically starts
rebuilding the drive. You can verify rebuild status by looking at the disk access
LED on the front of the disk module, or by checking disk status in Storage Utility.
6. Wait approximately 1 minute for the disk to initialize.
The disk ready LED is flashing.
7. To check rebuild status, do the following:
• Select the replacement disk icon in Storage Utility, then view the disk status in
the right-hand pane. You may need to refresh the Storage Utility display. On
completion, the drive status changes from Rebuilding to Online.
Содержание K2 BASECAMP EXPRESS
Страница 1: ...K2 STORAGE SYSTEM Instruction Manual SOFTWARE VERSION 3 2 071 8461 02 JULY 2007 ...
Страница 8: ...8 K2 Storage System Instruction Manual July 3 2007 Contents ...
Страница 14: ...14 K2 Storage System Instruction Manual July 3 2007 Safety Summaries ...
Страница 20: ...20 K2 Storage System Instruction Manual July 3 2007 Finding Information ...
Страница 24: ...24 K2 Storage System Instruction Manual July 3 2007 Chapter 1 Product Description ...
Страница 67: ...July 3 2007 K2 Storage System Instruction Manual 67 ...
Страница 68: ...68 K2 Storage System Instruction Manual July 3 2007 Chapter 2 Installing the Level 2 Storage System ...
Страница 172: ...172 K2 Storage System Instruction Manual July 3 2007 Chapter 4 Installing the Level 3 Storage System ...
Страница 236: ...236 K2 Storage System Instruction Manual July 3 2007 Chapter 5 Installing the Level 3R Storage System ...
Страница 282: ...282 K2 Storage System Instruction Manual July 3 2007 Chapter 6 Installing the Nearline Storage System ...
Страница 294: ...294 K2 Storage System Instruction Manual July 3 2007 Chapter 7 Description of K2 Storage Devices ...
Страница 300: ...300 K2 Storage System Instruction Manual July 3 2007 Chapter 8 Overview of K2 Storage Tools ...
Страница 390: ...390 K2 Storage System Instruction Manual July 3 2007 Chapter 11 Administering and maintaining the K2 Storage System ...