JUPITER — Release Notes
9
Pro-Bel SW-P-08 Protocol
Pro-Bel SW-P-08 Protocol
The 7.9.0 version of the Jupiter system supports two new protocol drivers,
for AccuSwitch, that implement parts of the Pro-Bel SW-P-08 protocol. The
first driver is implemented as a standard Remote Router control interface.
The second driver is implemented as an Automation, or as a Control panel,
interface.
Figure 2. Pro-Bel SW-P-08 Router Switcher Setup
This section will describe the needed setup and configuration steps to use
the Pro-Bel SW-P-08 protocol for:
•
Jupiter Router control
•
Remote Router control
Jupiter Router Control
You will need to configure the Jupiter CM-4000 or CM-4400 to use a Pro-Bel
SW-P-08 Router Control port. This is accomplished by adding entries in the
Serial Protocol and MPK Devices tables.
For steps to configure a CM-4000 or CM-4400 or modifying, compiling, and
validating a configuration set, see the CM 4000 Control Module or the CM-
4400 Control Module manuals.
Note
These steps assume that the CM-4000 or CM-4400 has been configured
properly.
Entering Serial Protocol Information
You may need to modify the Configuration set that is currently active; if so,
Grass Valley recommends that you make a copy for editing before making
these changes.
For more information about modifying the Configuration set, please see
the
CM-4000 or CM-4400 Control Module manuals
.
CM 4000
P8R or P08 protocol
“Hi speed serial” port
or
“Port 4”
Pro-Bel router
Any available serial port