5-8
7500 Series Instruction Manual
Section 5 — Maintenance and Troubleshooting
Thermal Control Module Reset 7500WB 256x256
The Thermal Control module monitors the temperature inside the matrix.
It controls fan speed and will shutdown the matrix if a critical temperature
condition occurs (temperature in excess of 80° C, 176° F). This is a fail-safe
feature. If a shutdown does occur all modules within the matrix should be
inspected. Once the cause of the critical temperature condition has been
identified and corrected, the Thermal Control module must be reset. Refer
to
To Reset the Thermal Control Module
1.
Remove cover screws. Set cover aside.
2.
Slide the module out at least one half inch to unseat the module.
3.
Reseat the module into the frame.
4.
Replace cover and secure with screws.
Figure 5-5. Thermal Control Module Reset
Note
The Thermal Control module can also be reset by removal and replacement
of all Power Supplies or unplugging and replugging the power cords.