3-8
■
Direct numeric input
(4)
Press the
M O D E
key to permit the P1 position to be selected by numeric input of the coordinates.
Use the
or
key to move to the column you wish to change (the selected column blinks).
To switch between
+
and
–
, press the
or
key. To set a numeral, press the
or
key until the
desired numeral is displayed.
X=+00000
Y=+00000
X=+00300
Y=+00000
(5)
When the desired position of P1 is displayed, press the
E N T E R
key.
To cancel the setting, press the
C A N C E L
key instead of the
E N T E R
key.
When the
E N T E R
key is pressed, the message below briefly appears and then the P2 position can be
set.
To set the P2 position, repeat Steps
(4)
and
(5)
.
P1
OK!
SetPoint
P2
(6)
When both the P1 and P2 points are set to the desired positions, press the
M O D E
key to return to Ready
mode.
NOTE
If the Sort mode is set to ON, the P1 or P2 point cannot be set from the control panel. Though the pen
carriage moves to the currently selected P1 or P2 point in Step
(3)
, you will not be able to proceed to Steps
(4)
through
(6)
.
Scaling