13
MEANING OF SYMBOLS
CAUTION
WARNING
ASSEMBLY/SETTINGS
INFORMATION
EQUIPMENT AND ACCESSORIES
1. Connector pipe
- 2 pcs
2. Connection
- 2 pcs
3. Blanking plug
– 2 pcs
PREPARATION FOR OPERATION
PUMP ASSEMBLY
There are two outlet holes in the pump base. When the connection is attached, it is possible to connect 2”
or 1½“ diameter hose (depending on your needs). Always use one of the holes for the connection, while the
other must be secured with blanking plug (
6
).
Ɣ
Attach appropriate connection (
4
) by screwing it into hole in the pump base.
Ɣ
Screw connector pipe (
5
) onto attached connection (
4
).
Ɣ
Join water hose and connector pipe (
5
).
PUMP INSTALLATION
Do not use the pump in a position, when it is not supported, but hung on water hose or power
supply cable.
Submersible pump should be hung on properly constructed support, hung on a cord or placed at the
bottom of a well. Keep bottom of the well clean and free from sludge to ensure proper operation of the
pump.
Float switch is adjusted so the pump can be switched on immediately, when the water level exceeds 50
cm.
You can install the pump:
-
to stiff pipes of a system for stationary use,
-
to flexible hoses of a system.
STATIONARY PUMP INSTALLATION
Ɣ
The pump must be placed on an even surface in the bottom of a well or a tank.
Ɣ
To enable appropriate operation and maintenance of the pump in safe conditions, observe minimum
required spacing between walls and other elements when placing the pump.
Ɣ
It is recommended to use pipes and connectors of the same size in the whole water system.
Ɣ
It is recommended to use non-return valve behind connector pipe of the pump.
Dimensions of well for the pump should be minimum 65 x 65 x 50 cm so the float switch can move
there freely.
CONNECTING TO ELECTRICAL POWER SUPPLY
Submersible pump is equipped with breakdown resistant plug. In accordance with valid regulations,
the pump allows connecting to safe socket of power network with parameters: 230 V AC, 50 Hz.
Connect the plug of the power cable only to mains socket with protective prong that is connected to
electrical circuit with residual current protection I
∆
n < 30mA or I
∆
n = 30mA.
In case the power cable or its plug are damaged, it is forbidden to repair those parts by one’s own
means. Entrust repair of power cord and the plug only to a qualified person. Only original parts
should be used.
Содержание 59G446
Страница 2: ......
Страница 4: ...4 1 5 6 4 2 3 A 2 50cm B 2 5cm...
Страница 16: ...16 59G446 IEC 364 30 30 Topex I 20 350 C 5...
Страница 17: ...17 1 2 3 4 5 6 1 2 2 2 3 2 2 11 2 6 4 5 4 5 50...
Страница 18: ...18 65 x 65 x 50 230 AC 50 I n 30 I n 30 2 A B 50 230 AC 50...
Страница 20: ...20 2 YYG 2 YY G GRUPA TOPEX Sp z o o Sp k ul Pograniczna 2 4 02 285 Warszawa...
Страница 21: ...21 59G446 IEC 364 30 30 I 20 35 C 5...
Страница 22: ...22 1 2 3 4 5 6 1 2 2 2 3 2 2 11 2 6 4 5 4 5 50...
Страница 23: ...23 65 x 65 x 50 230 50 I n 30 I n 30 2 A i B 50 230 50...
Страница 24: ...24 2 3 5 4 6 230 50 650 I IPX8 10 35 C 2 11 2 7 5 7 11500 x x 65 65 50 20 50 5 7 8 2016...
Страница 52: ...52 59G446 IEC 364 30mA 30ms I 20 mm 350 C 5 cm...
Страница 53: ...53 1 2 3 4 5 6 1 2 2 2 3 2 M 2 11 2 6 4 5 4 5 50 cm...
Страница 54: ...54 65 x 65 x 50 cm 230 V AC 50 Hz I n 30mA I n 30mA 2 A i B 50 cm 230 V AC 50 Hz O...
Страница 69: ...69 59G446 IEC 364 30 30 mA Topex 1 20 mm 350 C 5...
Страница 70: ...70 1 2 3 4 5 6 1 2 2 2 3 2 2 11 2 6 4 5 4 5 50...
Страница 71: ...71 65 x 65 x 50 230 V AC 50 Hz I n 30 mA I n 30 mA 2 A B 50 230 V AC 50 Hz...
Страница 91: ......
Страница 92: ...graphite pl...