23
Settings
4.7. -
∆ T Solar S3
4.8. - Tmax S3
4.9. - Priority S4
4.10. -
∆ T Solar S4
4.11. - Tmax S4
4.12. - Tmax S3
See „4.5. - Tmax S (X)“
See „4.5. - Tmax S (X)“
See „4.5. - Tmax S (X)“
See „4.4. - ∆ T Solar S (X)“
See „4.4. - ∆ T Solar S (X)“
See „4.4. - Priority S (X)“
4.13. - Tmax SB
4.14. - Tmax SB WT
Danger
Switch-off temperature at heat exchanger sensor
If this value is exceeded at the applicable sensor, the controller switches the associated pump and/or valve
off. If the temperature falls below this value again and the other conditions are also met, then the controller
switches the pump and/or valve on again.
Temperature values that are set too high can lead to scalding or damage to the system.
Scalding protection must be provided by the customer!
Switch-off temperature at pool sensor.
If this value is exceeded at the applicable sensor, the controller
switches the associated pump and/or valve off. If the temperature falls below this value again and the other
conditions are also met, then the controller switches the pump and/or valve on again.
Danger
Temperature values that are set too high can lead to scalding or damage to the system.
Scalding protection must be provided by the customer!
Temperature threshold for absolute priority
In systems with multiple storage tanks, charging of the lower-priority storage tank will never take place until
this set temperature setpoint at the storage tank sensor of the highest-priority storage tank is exceeded.
4.15. - T-priority
Interruption of charging into the lower priority storage tank
The charging of the lower-priority storage tank is interrupted after the settable time in order to check
whether the collector has reached a temperature level that allows charging in the higher-priority storage
tank. If so, the priority storage tank is charged. If not, the increase is measured (see „4.18. - Increase“), to
check if charging of the priority storage tank will be possible shortly.
4.16. - Loading time