This section enables the installer/commissioning engineer to record details of any parameters that may have changed during
commissioning.
Refer to Appendix A for full details of parameter settings.
level
Parameter
function description
Default
Value set on
commissioning
Group
code
I
21 00
Enable outgoing water set point
0=fixed set point
1=climatic curve
1
I
21 01
Fixed outgoing water set point
45.00
I
21 02
Maximum outgoing water temperature in Heating mode (Tm1)
45.00
I
21 03
Minimum outgoing water temperature in Heating mode (Tm2)
30.00
I
21 04
Minimum outdoor air temperature corresponding to maximum outgoing water
temperature (Te1)
-4
I
21 05
Maximum outdoor air temperature corresponding to maximum outgoing water
temperature (Te2)
20.0
I
31 01
DHW production priority setting
0=DHW is unavailable
1= DHW is available, and priority DHW over space heating
2= DHW is available, and priority space heating over DHW
1
I
31 21
Maximum time for DHW request
60
I
31 22
Minimum time for space heating
15
I
41 00
The heat pump turns ON/OFF based on
1=water set point
1
I
41 11
Maximum frequency of night mode
80
S
41 30
Maximum outgoing water set point in CH and DHW
55°C
I
42 00
Type of configuration of main water pump
0=always ON
1=ON/OFF based on buffer tank temperature
2=ON/OFF based on detect cycles
0
I
42 01
Time ON main water pump for detect cycle
3
I
42 02
Time OFF main water pump
5
I
42 03
Delay time OFF main water pump from OFF compressor
3
I
42 11
OFF time for unblock pump function start
48
I
42 12
Time ON main water pump for unblock pump function
5
I
42 20
Type of operation of additional water pump
0=disable
1=depending on main water pump setting
2=depending on main water pump setting but always OFF when the DHW mode is
activated
3=always ON, apart from if any alarms are activated or if the heat pump is in OFF
mode
0
S
43 00
Frost protection on room air temperature
0=disable
1=enable
1
I
43 01
Start temperature of frost protection on room air temperature
14.0
I
43 02
Hysteresis of room air temperature of frost protection
1.0
S
43 10
Frost protection on outdoor air temperature
0=disable
1=enable
1
I
43 11
Start temperature of frost protection on outdoor air temperature
4.0
I
43 12
Hysteresis of outdoor air temperature
3.0
I
43 14
Hysteresis of flow water temperature
3.0
S
43 20
Frost protection on outgoing water temperature
0=disable
1=enable
1
I
43 21
Start temperature of frost protection on flow water temperature
4.0
I
43 22
Hysteresis of flow water temperature
3.0
Appendix c
commissioning - Parameters record
Appendix c - commissioning - Parameters record
Page 69