background image

8

7

GrandCanyonGasLogs.com 

[email protected]

L.P. GAS APPLICATIONS

To avoid possible injury, fire and explosion, please read and 

follow these precautions and all instructions on appliance 

before lighting the pilot. L.P. (Propane) gas is heavier than air 

and will remain at floor level if there is a leak. Before lighting, 

sniff at floor level. If you smell gas, follow these rules:
1. Get all people out of building.
2. DO NOT light matches. DO NOT turn electrical lights    

or switches on or off in area. DO NOT use an electric    

fan to remove gas from area.
3. Shut off gas at L.P. tank outside of building.
4. Telephone gas company and fire department.  

  Ask instructions. Before hanging up, give your name,    

  address, and phone number.
DO NOT go back into the building. If help is coming, wait for 

them to arrive.
If L.P. tank runs out of fuel, turn off gas appliance. After L.P. 

tank is refilled, appliance must be relit according to manufac-

turer’s instructions. If the gas control has been exposed to 

WATER in any way, DO NOT try to use it. It must be re-

placed. DO NOT attempt repair on gas valve or appliance.
Tampering is DANGEROUS and voids all warranties.

WARNING

INSTALLATION

Coil the pilot tubing using proper bending techniques 

and insert the ¼

"

 flare end into the “PILOT” connec-

tion on the valve.  Wrench until tight. Fig. 5.

Coil the Thermopile lead and connect the terminals to 

the valve.  Color sequence does not matter, connect 

(1) lead to the TP and (1) lead to the TH/TP. Fig. 6.

For remote or wall switch installation, connect the 

ends of the terminal to the TH and the TH/TP  

connection on the valve. Fig. 7. 

FIG 5

FIG 6

FIG 7

Содержание HCMVQMKLP

Страница 1: ...fireplace where the unit is installed The installation including provisions for combustion ventilation air and required minimum permanent vent opening must conform with the National Fuel Gas Code ANSI Z223 1 NFPA 54 and applicable local building codes In Canada the installation must conform with the Natural Gas and Propane Storage and Handling Installation Code CSA B 149 1 A damper stop clamp is i...

Страница 2: ...tion 5 Installation 6 L P Gas Applications 8 Procedure for Lighting or Relighting 9 Service Instructions 10 Troubleshooting 12 Warranty 13 NOTE Changes may change without notice Changes will be shown on updated versions TABLE OF CONTENTS SPECIFICATIONS Refer to the burner owner s manual for minimum firebox dimensions Model BTUs N G L P 370 000 560 000 HCMVQM MAX BTU OUTPUT ...

Страница 3: ...EM WITH THE GLASS DOORS FULLY OPEN BOTH SIDES IF THE FIREPLACE IS A SEE THROUGH TYPE This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes Installation of appliances designed for manufactured homes or mobile homes must conform with Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 in the U S or wit...

Страница 4: ...mbly NG version 1 2A MV PILOT 18P 18 Millivolt Pilot Assembly LP version 1 3 US 4 8 1 2 x 1 2 Swivel Nut Union 1 4 46 88 Straight Connector 1 2 OD x 1 2 FIB 2 5 Heat Shield HC Millivolt Heat Shield 1 6 Reducer 3 2 3 4 to 1 2 Reducer 2 7 B5309 8 90º Elbow 1 2 2 8 113BS D Schedule 40 1 2 MIP Closed 1 9 1751 016 700 Series LP Conversion Kit LP Model only 1 3 2 1 5 4 6 7 8 ...

Страница 5: ...4 GrandCanyonGasLogs com customerservice grandcanyongaslogs com WIRE DIAGRAM MILLIVOLT ...

Страница 6: ...mum 10 W C Propane This Millivolt Control must be installed by a qualified professional service technician Instructions must be followed carefully when installing to ensure proper performance These instructions must be used as a supplement to the instructions supplied with the Grand Canyon Gas Logs burner system Follow the burner system instructions and make adjustments as appropriate for the addi...

Страница 7: ...NSTALLATION Leave the first two threads clean Never use compound on female threads as it might be pushed into the control body 6 The gas valve is multi position and can be mounted in any position except upside down without effecting its operation 7 Install gas valve so gas flow conforms with the inlet and outlet of the control 8 DO NOT insert any object other than suitable pipe or tubing in the in...

Страница 8: ...rom you Then install the other 48 88 into the B5309 8 and wrench until tight For ALL 2 Burners Glass Burners Kiva Burners front view and see through the 48 88 should point back towards the IN of the valve Fig 1 For 3 Burners and Jumbo Jumbo Slimline Burners front view and see through the 48 88 should be pointing up at a 45 degree angle Fig 2 Locate the US 4 8 1 2 x 1 2 flared swivel nut union fitt...

Страница 9: ... address and phone number DO NOT go back into the building If help is coming wait for them to arrive If L P tank runs out of fuel turn off gas appliance After L P tank is refilled appliance must be relit according to manufac turer s instructions If the gas control has been exposed to WATER in any way DO NOT try to use it It must be re placed DO NOT attempt repair on gas valve or appliance Tamperin...

Страница 10: ...r explosion may result causing property damage personal injury or loss of life LIGHTING INSTRUCTIONS FOR MILLIVOLT VALVE 1 STOP Read the safety information above on this label 2 Push in gas control knob slightly and turn clockwise to OFF NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 3 Wait five 5 minutes to clear out any gas If you smell gas STOP Follo...

Страница 11: ...ified for the system being checked clean and tighten thermo stat leads and connections shorten leads wires if possi ble or use heavier gauge wire Rapidly cycle thermostat to clean contacts or change the thermostat PROCEDURE FOR LIGHTING OR RELIGHTING Dials must be operated by hand DO NOT use pliers wrenches or other tools to turn dials The Gas Cock Dial has a dual function A Complete control of ga...

Страница 12: ... 1 Remove regulator adjustment screw cap Top of regulator 2 With small flathead screwdriver rotate adjustment screw clockwise to increase or counterclockwise to decrease pressure 3 Replace regulator adjustment screw cap REGULATOR CONVERSION OR REPLACEMENT CAUTION Main burner and pilot orifices must be changed when regulator is converted from one type of gas to another REGULATOR REPLACEMENT If it i...

Страница 13: ...leads are tight and attached to proper terminals see wiring diagram section pg 4 b Check valve using service instructions component check valve operator system c Replace valve 4 Burner system not burning properly a Low flame uneven flame a Check for low gas pressure should have operating pressures of 5 w c for natural gas 11 w c for propane at manifold 5 Burner system shuts down during operation a...

Страница 14: ...ginal purchaser only Indoor burners installed outside carry a 1 year warranty Electrical and Valves Grand Canyon Gas Logs valves remotes receivers carry a 2 year warranty against breakage or defects from date of purchase by original purchaser and must be installed be a licensed profes sional installer This warranty only covers use with Grand Canyon Gas Logs burners and logs In the event a defect o...

Страница 15: ...ALL US FIRST For immediate help with installation product information or if your product arrives damaged please call our toll free number at 1 602 344 4217 Monday Friday 8 00AM 5 00PM AZ Mountain Time or email us at customerservice grandcanyongaslogs com OUR STAFF IS READY TO PROVIDE ASSISTANCE ...

Страница 16: ...of enjoyment of our products Take a look at our other products from our RPG Brands family of companies Copyright 2022 RPG Brands Grand Canyon Gas Logs All rights reserved Products and specifications subject to change without notice The product images shown are for illustration purposes only and may not be an exact representation of the product ...

Отзывы: