28
Visual and acoustic settings
Push on and buttons at the same time in more than 6 sec. and the menu item [
A
] appears in the display.
With and buttons it’s possible to look through the main menu item [
A
] and [
P
]. Push on button to enter the
submenu from the main menu items.
With and buttons it’s possible to look through the submenus menu items. Push on button to enter the desired
menu item and adjust the setting with and buttons.
To confirm the new setting, push button. Leave the menu item and submenu with the button.
Menu access P+2
Alarm setup
A
A1 [° C] In case of condenser overheat, compressor protection cycle is started.
A2 [° C] Condenser temperature, which disconnects the compressor protection
cycle.
A3 [min]. Re-enter time for acoustic alarm (min.)
A4* On/off Activation of alarm history. History only works with alarm system:
LAL.
[1=on / 0=off]
A5*
Selection between A, E or F sensor for alarm systems
LAL
and
EAL
.
Apllies to both!
Display
presentation
P
P1 [min.] Temperature freeze after defrosting end.
P2 [° K] Temperature freeze around setpoint. Temperature fluctuation filter.
P3 [sec.] Display updating frequency.
P4
Selection of Celsius or Fahrenheit temperature scale.
*Might not be available, be available at limited or full extent, depending on programme variant and product.