background image

 

765041996 

Rev. 001 

 
 

Operating the product

 

 
Connect the product to the socket. This is done by mounting the accompanying power cord 
first as shown in Fig. 4, and then subsequently connecting the cord to the socket.  
 
To switch the product on and set the desired temperature for the cabinet, the uppermost 
panel must be flipped up and held in that position. 
 
NOTE:  

Note that the panel does not stay up by itself, but rather must be held up when 
it is opened. 

 

 

 

Fig. 6  

 
When the product has been connected to the power supply, but not switched on yet (in 

standby), this is indicated by a small control lamp

 which is the only one lit in the lower 

right corner of the display. 

To switch the product on, press 

 

for approx. 3 seconds. During start-up, the control 

lamp 

 will blink until the product is on. 

 
The display will show the current temperature in the product. This also serves to indicate 
that the power supply is connected to the product. 

The product is switched off in the same manner as it is switched on. By pressing 

 

 

 

for approx. 3 seconds. 
 
To switch on and off both the interior light in the product and the light in the display box, 
above the door, use the switch placed immediately to the left of the controls behind the 
display box. To gain access to this switch, rotate the display box upwards as shown in Fig. 
6.

 

 

Содержание Eco Euro KG 60

Страница 1: ...765041996 Rev 001 1 Operating and servicemanual Eco Midi KG FG 60 82...

Страница 2: ...g the product 3 Temperature setting 4 Keyboard lock 4 Alarms 5 Error codes on the display 6 Defrosting 7 Setting the configuration parameters 8 Manufacturer s settings 9 Working setpoint and configura...

Страница 3: ...this is indicated by a small control lamp which is the only one lit in the lower right corner of the display To switch the product on press for approx 3 seconds During start up the control lamp will b...

Страница 4: ...mpressor is running Alternatively by not touching the keys for a minimum of 15 seconds the controls will switch back to the normal temperature display and the value that has been set will be saved aut...

Страница 5: ...is shown in the display if the condenser temperature has been too high Clean the condenser filter in front of the condenser Refer to the placement of the filter in Fig 3 CSd Compressor shut off This...

Страница 6: ...Control lamp for defrosting Lit continuously during defrosting Blinks while draining after completed defrosting Control lamp for evaporator fan Lit continuously when the evaporator fan is in operatio...

Страница 7: ...ng is automatically performed 4 times every 24 hours by a defrost heating element Manual defrosting If the cabinet is operating under severe load frequent door opening and frequent replenishment manua...

Страница 8: ...765041996 Rev 001 8 Setting the configuration parameters...

Страница 9: ...765041996 Rev 001 9 Manufacturer s settings...

Страница 10: ...t air temperature 4 if P4 0 1 o 2 if P4 3 inlet air temperature P7 0 100 50 50 50 50 50 inflowing air temperature percentage for the calculation of the CPT temperature P8 0 250 0 1 s S 100 100 100 100...

Страница 11: ...d16 0 evaporator fan activity will depend on F2 parameter if d16 0 the evaporator fan shall remain off d8 0 3 0 0 0 0 0 defrost activation methods 0 AT INTERVALS FOR TIME defrost will be activated on...

Страница 12: ...aporator fan operation when the compressor is turned off see also F7 only if F0 2 PARAM MIN MAX U M DEF GRAM FG HAV GRAM KG HAV GRAM FG FAV GRAM KG FAV DIGITAL INPUTS i0 0 5 5 2 2 2 2 effect caused by...

Страница 13: ...w consumption function is activated 0 the mode shall never be aactivated PARAM MIN MAX U M DEF GRAM FG HAV GRAM KG HAV GRAM FG FAV GRAM KG FAV VARIOUS key activation POF 0 1 1 1 1 1 1 1 YES PAS 99 999...

Страница 14: ...condenser temperature falls below the value set with parameter F11 provided that the compressor is switched off 22 the compressor is switched off 10 s after the activation of the input if the input i...

Страница 15: ...765041996 Rev 001 15 Wiring diagram...

Отзывы: