9
EN
A1
A3
A2
A4
Erroneous connection could lead to overheating of the terminal board which could lead to blowout and elec-
tric shock.
Check that all the connections are tight before connecting the oven to the mains.
E = Yellow/Green
: “EARTH” protection conductor.
N = Blue
: neutral conductor.
L1, L2, L3 = Brown, Grey, Black
: live conductors
Check there is no static discharge between live and earth. Check the limit switch continuity between the ex-
ternal casing and the earth wire of the mains. It is advised to use a multi tester to carry out these operations.
5.2 CABLE SUBSTITUTION
This must be carried out by a qualified authorized
technician. The earth wire must always be yellow
green.
WARNING: the yellow/green voltage wires in the
earth cable must be 3 cm longer than the others.
Proceed as follows to connect the power supply
wire to the terminal board:
• (A1) Loosen the tops of the cable gland and open
the side part of the appliance by loosening the
screws.
• (A3) Loosen the terminal screws and feed the cable
conductors through. Take out the old cable from
the cable gland.
• (A2) Feed the new cable through the cable gland.
Connect the new cable’s conductors to the ter-
minal following the connection diagram on the
label at the lower part of the back of the appli-
ance. Only connect what is indicated inserting the
copper bridge and the electricity cable together
under the screws, in the tightening direction,
so the cable and the bridge are tightly fi xed by
tightening the screw. The type of cable to be used
(HO7RN-F) is indicated on the label for each con-
nection and the voltage sections in mm².
• (A4) Close the side part of the appliance by tight-
ening the screws and fi t the cable by tightening
the cable gland top.