I/O
Yd.0
Yarn
Detector
Operating
Mode
Using this
mode, a Yarn
Detector can
be attached
to the
System
which
control star
and stop of
the pump
□
MODE
Yd.0..Yd.2
In addition to the release of the pump
supply by means of an external release
signal and clock control, a pump release
can optionally be carried out with an
externally connected Yarn Detector.
Yd.0: No Yarn Detector used
Yd. 1: Yarn Detector with active-high
output signal used
Yd. 2 Yarn Detector with active-low output
signal used
Default-value: Yd. 0
□
I/O
dP.0
Motor
decade and
gear setting
sets lub
quantity
decade
setting
□
MODE
dP.0 /
d.P1 /
d.P2
dP.0: Feeding Quantity Input with 1 decade
after comma (e.g. 12.3 g/min)
dP.1: Feeding Quantity Input with 2
decades after comma
(e.g. 1.23 g/min)
dP.2: Feeding Quantity Input with 2
decades after comma
–
only for use
with 10:1 motor gear
(e.g. 1.23 g/min)
Default value: dP.0
□
I/O
L.20
Maximum
Feeding
Quantity
Limitation
Limits the
max.
Adjustable
Lub Quantity
□
MODE
L.05 ..L.40
This value limits the maximum settable
feeding quantity in operation mode to the
value set here, given in grams per minute
for non-clock-operation and grams per
1000 m of thread in clock operation
respectively.
Default-value: L.20
Instruction Manual GRAF SINGLE LUB 2 / Version 4.0
–
05.2020