6. The small wastewater treatment system's control unit
27 / 54
Displaying settings
6.3.6
The current control unit settings can be viewed under this menu item. These settings cannot be
changed. This menu item is used to analyse the settings without changing them.
Service menu and action code
6.3.7
Operating parameters can be changed in the Service menu. Access is protected by a code.
The operating parameters can also be changed using a particular action code. This second
maintenance level is reserved for qualified specialists only!
No claims for warranty can be made if the control unit settings are accessed
without authorisation!
Changing fuses
6.4
Before fuses are changed, the system should be switched off using the red maintenance
switch!
To change or check the fuses, the control and machine cabinet must be opened using the key
provided.
The microfuses described above are located on the rear of the control unit.
Fuses used:
230 V / 50 Hz mi-
crofuse
KLbasic KLplus
KL24plus
KL24base
F1 supply
8 A, medium slow
blow
6.3 A, slow blow
Consumer F2
2 A, slow blow
-