Flush
b. Trigger gun, slowly open regulator
adjustment knob (G) until pump beings to
cycle and a steady stream comes from gun.
Trigger gun for 10-15 seconds.
Note
If using an AA gun, increase air
pressure by turning gun regulator
clockwise.
c. After solvent is running clean, turn the
regulator adjustment knob (G) counter
clockwise until it stops and the gauge reads
zero. The pump will stop. Once the material
stops flowing, release the trigger and engage
the trigger lock. Stop the pump with the rod
buried in the pump.
d. Close the bleed type master air valve.
8. If flushing through drain/purge valve:
a. Place drain tube in a grounded waste pail.
Open drain/purge valve (J) slightly by rotating
counterclockwise.
Left: Xtreme Lower
Right: Dura-Flo
Lower
b. Start the pump by rotating the air regulator
adjustment knob (G) clockwise until pump
begins to move.
c. When clean solvent flows from drain tube
close drain/purge valve (J) by rotating
clockwise. Pump will stall.
Left: Xtreme Lower
Right: Dura-Flo
Lower
d. Stop the pump with the rod buried in the
pump.
e. Follow
Pressure Relief Procedure, page 14
.
Leave solvent in and store sprayer.
9. Remove fluid filter and soak in solvent. Replace
filter cap.
16