Air
Air
Air Connections
Connections
Connections
Connect an electrically conductive 1/2 in. ID (minimum) air hose to supply air to the system air controls.
Packages without an elevator will not have an elevator control, and packages without a feed pump will have
the connection for the pump air hose plugged. Install an air filter upstream of the system to remove harmful dirt
and moisture from the air supply. To order an air filter, order part 106148 (3.8 in. npt, 20–micron element, 5 oz.
bowl, without gauge).
Ref.
Ref.
Ref.
Description
Description
Description
AR
Air Restrictor (Elevator Speed)
EC
Elevator Control Selector
AS
Agitator Shut Off Valve
FP
Feed Pump Shut Off Valve
SA
Supply Air Inlet
LB
Agitator Lubricator
RG
Agitator Regulator and Gauge
EF
Elevator Air Fitting
If installing an elevator, reference the Installation section of the Elevators and Pump Supports Manual 306287*.
To connect the elevator air control, insert 1/4 in. OD air tubing into the tube-connect fitting of the resistor valve
(AR) on the back of the elevator air control. Insert the other end into the elevator air fitting (AF).
* Install the elevator air fitting (EF, included with the elevator air control) into the port on top of the elevator
riser tube.