Graco Trabon LC-1000 Скачать руководство пользователя страница 8

Your Program Record

Company:   _____________________________________  By:   _______________________

Machine Identi

fi

 cation:   __________________  

 

Date:   _____________________

System Type:   Bi-Flo   ___  Piston Distributor   ___  Series   ___  Other:   _________________

On (Monitor) Value:  Time/Count   _____  Seconds ___ Minutes ____Hours  ___ Counts _____

Off Value: Time/Count  _______ Seconds ______ Minutes ______ Hours  ____ Counts ______

Cycle Value (Switch Transitions):   ______________________

Pump On (Pulsed/Non Pulsed):   ____________ (00 is NonPulsed)

TROUBLESHOOTING

Symptom

Cause

Remedy

Blank Display, No LEDs

No Power

Check Wiring & Fuse-Repair as Required

Bad Circuit Board

Replace Circuit Board

No Display or Black Dis-
play, but System Operates

Temperature too High or too Low

Move Controller to Location that is within 
Temperature Limits

Bad Display

Replace Circuit Board

Program Will Not Run

Programming Error or Bad Circuit 
Board

Review Instructions & Examples-Reprogram/
Replace Circuit Board as Required

In Programming Mode

Exit by Pressing PRGM

Can’t Change Program

Programming Error or Bad 
Circuit Board

Review Instructions & Examples-Reprogram/
Replace Circuit Board as Required

Power Off Before Programming 
Completed

Complete the Programming Process Before 
Removing Power

Fault Light On

No Cycle Input

Check Cycle Switch & Wiring-Repair as Required

Level Sw. or HP Sw. Closed 
(If Used)

Check Reservoir Level and Operating Pressure-
Re

fi

 ll/Repair as Required

System Blockage

Correct Blockage (see Bul 30101)

No Pump Flow or Low Flow

Check Reservoir Level & Pump 
Output-Re

fi

 ll/Repair as Required

Main Line Leaks

Check & Repair as Required

Plugged Filter/Strainer

Clean or Repair as Required

Monitor Time too Short

Increase Monitor Time

Failure to Indicate a Fault

Cycle Count Set to 00

Set Cycle Count to Desired Number of Half-Cycles.

Programmed Machine Count 
Mode, and Wire According to 
Fig. 1

Program On and Off in Time Mode, or Wire per 
Fig. 2.

Call today for product information or to request a demonstration.

1.800.USA.LUBE 

(1-800-872-5823) or visit us at www.lubriquip.graco.com. 

All written and visual data contained in this document are based on the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice

All other brand names or marks are used for identification purposes and are trademarks of their respective owners. 

®2006 Graco Inc. Bulletin 14540, July 2000. Printed in U.S.A.

Содержание Trabon LC-1000

Страница 1: ...put Loading Main Pump Load 12 VDC 230 VAC 50 60 Hz 10 Amp Relay Output External Fused by User Fault Output Signal 12 VDC 230 VAC 50 60 Hz 1 Amp Resistive Max N O Dry Isolated Contact External Fused by...

Страница 2: ...MANUAL RUN SW SENSE 10 11 12 13 14 15 16 17 18 19 CYCLE SWITCH SEE NOTE 2 SW IN SW FAULT FAULT DO NOT USE FIG 2 INPUT OUTPUT DRY CONTACT SEE NOTE 1 12 VDC DO NOT USE CLOSURE OF SWITCH CONTACTS CAUSES...

Страница 3: ...w the remaining time left in either an ON or OFF cycle as indicated by the icons Timing can be done in seconds minutes hours or counts A flashing LCD character indicates that the timer is in the Progr...

Страница 4: ...Change the value using the S key and X key c Press the ENTER key to accept the new value The SEC MIN HR CNT icon will blink d Press ENTER to accept the time base or the S key to scroll through the tim...

Страница 5: ...Volume 6 0 cu in 99 cc per hour AL 50 Pump Used 24 cu in per stroke 3 9 cc Master Divider Volume per Cycle 15 cu in 2 4 cc Cycle Interval 15 Minute 1 4 hour Used Volume per Lube Cycle 6 0 cu in 4 1 5...

Страница 6: ...Press ENTER Key to accept value SEC MIN HR CNT blinks d Use S Key to scroll through choices select SEC e Press ENTER Key to accept choice OFF Icon blinks 3 OFF Pause Time a Press ENTER Key OFF TIME CO...

Страница 7: ...TO 00 Non pulsed output c Press ENTER Key to accept value LCD returns to DISPLAY mode Programming is now complete To verify lube sequence initiate a manual lube cycle by pressing MANUAL RUN button NO...

Страница 8: ...Reprogram Replace Circuit Board as Required Power Off Before Programming Completed Complete the Programming Process Before Removing Power Fault Light On No Cycle Input Check Cycle Switch Wiring Repair...

Отзывы: