LC-1000 Lube System Controller

INPUT

VOLTAGE

HOT

NEU

PUMP

PUMP

1

2

3

4

5

6

7

8

9

MANUAL

RUN

10

11

12

13

14

15

16

17

18

19

CYCLE

SWITCH

(SEE NOTE 2)

+

-

+

-

F

AUL

T

F

AUL

T

DO NOT

USE

OPTIONAL

LOW-LEVEL SWITCH
AND/OR HIGH PRESSURE
SWITCH. BOTH MUST BE
OPEN DURING NORMAL
SYSTEM OPERATION.

FIG 1

Option for units built after February 1, 1999 that are programmed in time mode.

INPUT

OUTPUT

DRY

CONTACT

(SEE NOTE 1)

12 VDC

DO NOT USE

JUMPER

INSTALLED

WIRING INFORMATION

All units programmed in machine count mode, or any units built prior to Februay 1, 1999.

Option for units built after February 1, 1999 that are programmed in time mode.

INPUT

VOLTAGE

HOT

NEU

PUMP

PUMP

1

2

3

4

5

6

7

8

9

MACHINE COUNT

(SEE FIG 3 THRU 5)

MANUAL

RUN

SW

SENSE

10

11

12

13

14

15

16

17

18

19

CYCLE
SWITCH
(SEE NOTE 2)

+

-

+

-

+

SW

IN

SW

-

F

AUL

T

F

AUL

T

DO NOT

USE

FIG 2

INPUT

OUTPUT

DRY

CONTACT

(SEE NOTE 1)

12 VDC

DO NOT USE

CLOSURE OF SWITCH CONTACTS
CAUSES LC-1000 TO INDICATE A FAULT
CONDITION.

BUT PUMP WILL CONTINUE

TO OPERATE.

Note 1: 12 VDC with 12 VDC Input Voltage

24 VDC with 24 VDC, 115 VAC and 230 VAC Input Voltage

Note 2: Piston Distributor or Injector System will use a Pressure Switch.

CLOSURE OF SWITCH CONTACTS
CAUSES LC-1000 TO INDICATE A FAULT
CONDITION. ON EXPIRATION OF THE
NEXT ON (MONITOR) PERIOD.

SUSPENDING OPERATION OF THE PUMP.

OPTIONAL

LOW-LEVEL SWITCH
AND/OR HIGH PRESSURE
SWITCH. BOTH MUST BE
OPEN DURING NORMAL
SYSTEM OPERATION.

FIG 5

10

11

12

13

SINK SWITCH -

2 OR 3 WIRE TYPE

10

11

12

13

DRY CONTACT SWITCH

FIG 3

10

11

12

13

FIG 4

10

11

12

13

SOURCE SWITCH -

2 OR 3 WIRE TYPE

Figure 3, 4 and 5 refer to machine count input only.

WIRING INFORMATION

Содержание Trabon LC-1000

Страница 1: ...put Loading Main Pump Load 12 VDC 230 VAC 50 60 Hz 10 Amp Relay Output External Fused by User Fault Output Signal 12 VDC 230 VAC 50 60 Hz 1 Amp Resistive Max N O Dry Isolated Contact External Fused by...

Страница 2: ...MANUAL RUN SW SENSE 10 11 12 13 14 15 16 17 18 19 CYCLE SWITCH SEE NOTE 2 SW IN SW FAULT FAULT DO NOT USE FIG 2 INPUT OUTPUT DRY CONTACT SEE NOTE 1 12 VDC DO NOT USE CLOSURE OF SWITCH CONTACTS CAUSES...

Страница 3: ...w the remaining time left in either an ON or OFF cycle as indicated by the icons Timing can be done in seconds minutes hours or counts A flashing LCD character indicates that the timer is in the Progr...

Страница 4: ...Change the value using the S key and X key c Press the ENTER key to accept the new value The SEC MIN HR CNT icon will blink d Press ENTER to accept the time base or the S key to scroll through the tim...

Страница 5: ...Volume 6 0 cu in 99 cc per hour AL 50 Pump Used 24 cu in per stroke 3 9 cc Master Divider Volume per Cycle 15 cu in 2 4 cc Cycle Interval 15 Minute 1 4 hour Used Volume per Lube Cycle 6 0 cu in 4 1 5...

Страница 6: ...Press ENTER Key to accept value SEC MIN HR CNT blinks d Use S Key to scroll through choices select SEC e Press ENTER Key to accept choice OFF Icon blinks 3 OFF Pause Time a Press ENTER Key OFF TIME CO...

Страница 7: ...TO 00 Non pulsed output c Press ENTER Key to accept value LCD returns to DISPLAY mode Programming is now complete To verify lube sequence initiate a manual lube cycle by pressing MANUAL RUN button NO...

Страница 8: ...Reprogram Replace Circuit Board as Required Power Off Before Programming Completed Complete the Programming Process Before Removing Power Fault Light On No Cycle Input Check Cycle Switch Wiring Repair...

Отзывы: