LC-1000 Lube System Controller

OPERATION

When power is applied, the green “POWER LED”lights 
and the LC-1000 counts down alternately from the 
programmed “OFF/ON” Times/Counts to zero.

In the “ON” (Monitor) mode, the ” PUMP LED” lights.
The pump is activated and both the “ON and “RUN” 
icons are displayed. If the programmed number of 
cycle switch transitions (1/2 cycles) are received  be-
fore expiration of the “ON” (Monitor) period, the PUMP 
OUTPUT, “PUMP” LED, “ON” and “RUN” icons turn 
off and the “OFF” icon will display. If the programmed 
number of cycle switch transitions (1/2 cycles) are 
not received before expiration of the “ON” (Monitor) 
period, a “Fault” will be registered. This suspends 
pump operation, turns off  the ” PUMP” LED, the “ON 
and “RUN” icons, turns on the red “FAULT” LED and 
closes the fault output contacts.

If a pulsed output to the pump is required, a “PUMP 
ON” time may be programmed from 0 to 99 seconds. 
Setting this value to zero will provide a steady state 
output. “PUMP OFF” is 

fi

 xed at 3 seconds.

The “RUN” icon will display anytime the pump out-
put is energized. During pulsed pump operation, the 
“RUN” icon will 

fl

 ash on and off in sequence with the 

pump. During continuous running, the “RUN” icon will 
not 

fl

 ash. 

The Controller is programmed to retain the Time/Count 
in memory when power is turned off. This feature pre-
vents excessive lubrication in start/stop applications 
and retains information for cycle to be completed when 
power is restored.

CHANGING SETTINGS

From the Timer display mode, pressing the “PRGM” 
button will allow you to review or change between the 
set “ON” (Monitor), “OFF”, “CYCLE, “PUMP” (Pulsed 
On Time) and “DISPLAY” modes. When in the pro-
gramming mode, the icons/digits will blink. When in 
the display mode, the icons/digits do not blink.

1.  To set a new “ON” (Monitor) Time/Count, press  
 

the “PRGM” key until the “ON” icon blinks. The  

 

current “ON” (Monitor) Time/Count will be 

 displayed.
 

a)  Press the “ENTER” key. The “ON” (Monitor)  

 

    Time/Count digit will blink. 

 

b)  Change the value using the 

S

 key and 

X

  

    key. 
 

c)  Press the “ENTER” key to accept the new  

 

    value. The “SEC/MIN/HR/CNT” icon will blink

 

d)  Press “ENTER” to accept the time base or the  

 

   

S

 key to scroll through the timing choices. 

 

e)  Press “ENTER” to complete the process (Note:   

 

    Monitor period is normally set 2 times the  

 

    actual time required for the pump to satisfy the  

    system 

cycle 

requirements).

2.  The “OFF” icon will now be blinking. 
 

a)  Repeat above process until all “OFF” 

 

    options have been programmed. 

 

b)  Press “ENTER” to accept the new values. 

3.  The “CYCLE” icon will now be blinking
 

a)  Press “ENTER” and the cycle value 

 

    (1/2 cycles) will blink. 

 b) Using 

the 

S

 and 

X

 keys set the cycle 

    value 

as 

follows: 

 Series Progressive:

 ...............02 (1 divider cycle), 

    04 (2 divider cycles), 06 (3 divider cycles), etc.
 

Dual Line:

 ................. 01 (half cycle) 02 (full cycle)

 

Piston Distributor or Injector:

 .........................01

 

c)  Press “ENTER” to register the new value.  

4.  The “PUMP” icon will now blink.  
 

a)  Press “ENTER” again and the pump 

 

    pulsed “ON” time will blink.  

 

b)  Using the 

S

 key and 

X

 key, set the value 

   (seconds) 

as 

follows:

 Self-Cycling Pump 
  (Motor Driven, or Reciprocating Barrel):

 ......00

 

Single Shot Pump 

  (Piston Distributor, or Injector):

  ...................00

 

Single Shot Pump 

  (Recycle for Series Progressive):

 ........03 to 10

c)  Press "ENTER" to accept the new values.

NOTE:

  In the Recycle mode, PUMP “OFF” time is  

 

fi

 xed at 3 seconds.  Press “ENTER” to register  

 

the new value and return to the “DISPLAY”  

 mode.

NOTE:

  Scrolling through the modes using the“PRGM”  

 

key only will allow the review of the current  

 

settings without changing any of the values or  

 

timing.  It is recommended that programming  

 

not be attempted while a lube cycle is in 

 

process.  After making any change in settings,  

 

activate a manual run to initiate the change.

NOTE:

  Programming examples for speci

fi

 c types of 

systems are shown on pages 5, 6 and 7. 

MANUAL RUN / RESET

A manual-run lubrication cycle may be initiated by 
pressing the manual run button, located on the left 
underside of the unit, OR by shorting terminals 14 
and 15 together, such as with a remote push-button 
momentary switch.  Manual run may also be initiated 
by pressing 

S

 and "ENTER" keys together.  Manul run 

is also used to reset the controlelr and to clear faults.

Содержание Trabon LC-1000

Страница 1: ...put Loading Main Pump Load 12 VDC 230 VAC 50 60 Hz 10 Amp Relay Output External Fused by User Fault Output Signal 12 VDC 230 VAC 50 60 Hz 1 Amp Resistive Max N O Dry Isolated Contact External Fused by...

Страница 2: ...MANUAL RUN SW SENSE 10 11 12 13 14 15 16 17 18 19 CYCLE SWITCH SEE NOTE 2 SW IN SW FAULT FAULT DO NOT USE FIG 2 INPUT OUTPUT DRY CONTACT SEE NOTE 1 12 VDC DO NOT USE CLOSURE OF SWITCH CONTACTS CAUSES...

Страница 3: ...w the remaining time left in either an ON or OFF cycle as indicated by the icons Timing can be done in seconds minutes hours or counts A flashing LCD character indicates that the timer is in the Progr...

Страница 4: ...Change the value using the S key and X key c Press the ENTER key to accept the new value The SEC MIN HR CNT icon will blink d Press ENTER to accept the time base or the S key to scroll through the tim...

Страница 5: ...Volume 6 0 cu in 99 cc per hour AL 50 Pump Used 24 cu in per stroke 3 9 cc Master Divider Volume per Cycle 15 cu in 2 4 cc Cycle Interval 15 Minute 1 4 hour Used Volume per Lube Cycle 6 0 cu in 4 1 5...

Страница 6: ...Press ENTER Key to accept value SEC MIN HR CNT blinks d Use S Key to scroll through choices select SEC e Press ENTER Key to accept choice OFF Icon blinks 3 OFF Pause Time a Press ENTER Key OFF TIME CO...

Страница 7: ...TO 00 Non pulsed output c Press ENTER Key to accept value LCD returns to DISPLAY mode Programming is now complete To verify lube sequence initiate a manual lube cycle by pressing MANUAL RUN button NO...

Страница 8: ...Reprogram Replace Circuit Board as Required Power Off Before Programming Completed Complete the Programming Process Before Removing Power Fault Light On No Cycle Input Check Cycle Switch Wiring Repair...

Отзывы: