![Graco ToughTek MP40 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/graco/toughtek-mp40/toughtek-mp40_operation-manual_2251031018.webp)
Operation
18
3A4349B
Winterizing and Extended
Storage
1.
Connect the power cable to the appropriate power
source and turn the main power disconnect switch
(T) to ON.
2.
If connected to the water pump inlet, disconnect the
water feed hose.
3.
Disconnect the water assembly hose (WH) from the
water assembly control inlet (WC). Loosen the drain
cock (DC) behind the water flow meter, fully open
the water flow meter valve (R), and then open the
spray gun latch (S) on the water wash-down hose.
4.
Press and hold the water prime button (Y) until
water has stopped draining from all openings, then
release the button.
5.
Press the water pump button (Z) to turn the water
pump on and let it run for 15 seconds to expel any
excess water. Press the button again to stop the
water pump.
6.
Turn the main power disconnect switch (T) to OFF
and disconnect from the power supply.
7.
Leave all components open and detached until the
next use.
8.
Make sure the motor has been fully greased and the
mixing pump has been thoroughly cleaned and no
material remains.
Startup After Extended Storage
Reassemble all disconnected hoses and close all water
drain openings before startup.
If the pump will not startup after an extended period of
storage, perform the following steps:
1.
Loosen the three bolts on the end cap by approxi-
mately two turns.
2.
Insert a flat screwdriver blade into the provided slots
between the end cap and the pump head.
3.
Gently pry on both sides until the cover lifts off the
pump head.
4.
Restart the water pump and observe that it starts up
and operates correctly. While the pump is running,
tighten the three bolts.
5.
Press the water pump button (Z) to turn off the water
pump and press and hold the water prime button
(Y).
6.
Slowly open the flow meter valve until water can be
seen passing through the flow meter.
7.
Release the water prime button (Y) and make sure
the water has stopped. The mixing pump is now
ready for use.
WLD
:+
6
5
'&
:&
ti29595a
X2
Содержание ToughTek MP40
Страница 26: ...Parts 26 3A4349B MP 20 and MP 40 Series Parts continued WL D Apply pipe sealant to pipe threads 8...
Страница 32: ...Parts 32 3A4349B Drive Shaft Ref 7 MTA712 for MP 20 MP 20 16A MTA713 for MP 40 MP 40 380V 07 BWL D 07 BWL D...
Страница 37: ...Notes 3A4349B 37 Notes...
Страница 43: ...Dimensions for all models 3A4349B 43 Dimensions for all models WL D 53 134 cm 64 163 cm 45 5 116 cm 32 25 82 cm...