31
310–534
Heated Pump Troubleshooting
For more information about the Check-Mate 800 Displacement Pump, see Form# 308–570. For more information
about the Therm-O-Flow Pump Module, see Form# 310–530.
Problem
Cause(s)
Solution(s)
Rapid down stroke or up stroke
(pump cavitation)
Material not heated to proper
pumping temperature.
Check and adjust temperature set point.
(p
p
)
Air is trapped in pump.
Bleed air from the pump using this pro-
cedure:
1.
Place a waste container under the
pump bleed port.
2.
Open the bleed port part way.
3.
Turn on air to the pump
4.
Allow material to flow from the bleed
port until it is air-free.
5.
Shut off air to the pump and close
the bleed port.
6.
Turn air on to the pump and set the
pump air regulator for normal opera-
tion.
Downstroke: Lower check in
pump is worn.
Upstroke: Upper check in pump is
worn.
Rebuild and replace pump, as neces-
sary.
Material leaks around pump outlet
Outlet fitting is loose.
Tighten outlet fitting.
Material leaks around bleed port
Bleed port fitting is loose.
Tighten bleed port fitting.
Pump won’t move up or down
Problem with air motor.
See Air Motor Troubleshooting chart on
page 32.
Foreign object lodged in pump.
Remove object and rebuild pump
assembly.
WARNING
To reduce the risk of serious injury
whenever you are instructed to relieve
pressure, always follow the Pressure
Relief Procedure (page 20).
Before attempting to dislodge a foreign
object:
1.
Relieve system pressure.
2.
Remove the pump from the air
motor.
Wet-cup leaks
Worn throat seal.
Replace wet-cup and throat seal pack-
ings.
Содержание Therm-O-Flow 55-H
Страница 39: ...39 310 534 Service Fig 21 1391 1401 1321 1331 1791 1841 To Ram Junction Box For 240 VAC Supply Units ...
Страница 40: ...40 310 534 Service Fig 22 1391 1401 1321 1331 1791 1841 To Ram Junction Box For 480 575 VAC Supply Units ...
Страница 42: ...42 310 534 Notes ...
Страница 60: ... 310 534 Electrical Control Panel and Wiring for C32428 240 VAC Lines 100 121 122 122 ...
Страница 64: ...64 310 534 Electrical Control Panel and Wiring for C32428 240 VAC Lines 200 220 ...
Страница 65: ...310 534 65 Notes ...
Страница 66: ... 310 534 Electrical Control Panel and Wiring for C32429 480 VAC 122 122 Lines 100 121 ...
Страница 70: ...70 310 534 Electrical Control Panel and Wiring for C32429 480 VAC Lines 200 220 ...