17
310–534
Installation
To disconnect a temperature controller:
WARNING
ELECTRIC SHOCK HAZARD
Do not open the electrical control panel,
unless you are a qualified electrician.
Before opening the control panel, make sure that
all power has been removed from the control panel.
1.
Make sure the power is off and that the disconnect
switch is in the OFF position.
2.
Open the electrical control panel. The temperature
controller mounting holes are located in the door of
the control panel.
3.
For each unused temperature controller (Fig. 8):
a.
Disconnect the power wire, (wire 1162), in the
number 9 position on the back of the tempera-
ture controller.
b.
Maintain the integrity of the electrical connec-
tions by connecting the jumper wire to the
number 9 position of a temperature controller
that is being used.
Two Temperature Zones Inactive
Fig. 8
Power
Lead
Neutral