10
310–534
Installation
The installation procedure includes:
D
locating and installing the ram and hydraulic power
supply. See Form#310–533 for installation informa-
tion.
D
electrically connecting hoses to the electrical con-
trol panel
D
grounding the system
D
connecting the electrical control panel to a power
source
D
checking resistance
D
setting controls on the electrical control panel
D
starting up the system
D
initially loading material
Installing the Ram and Hydraulic Power
Supply
To install the ram and hydraulic power supply, follow
the installation procedure in Form# 310–533, Hydraulic
Powered Ram Modules. See the ram mounting and
clearance dimensions drawing (Fig. 36 on page 72) for
ram mounting and clearance dimensions. See the
hydraulic power supply dimensions drawing (Fig. 37 on
page 73) for hydraulic power supply clearance dimen-
sions.
Electrically Connect Hoses to the
Electrical Control Panel
WARNING
FIRE HAZARD
Only use hoses that have a maximum
wattage less than or equal to 1250
watts. Using hoses with higher maximum wattage
could create a runaway temperature condition.
Assemble the hose and gun components as needed.
For information on connecting the hose and gun com-
ponents, follow the gun’s instructions.
Electrically connect the hoses to the electrical control
panel. The connectors are located on the back of the
electrical control panel (Fig. 3).
1.
Connect the plug from hose 1 to the Hose 1/Gun 1
receptacle (1).
2.
Connect the plug from hose 2 to the Hose 2/Gun 2
receptacle (2).
Fig. 3
Rear View of Electrical Control Box
1
2
Содержание Therm-O-Flow 55-H
Страница 39: ...39 310 534 Service Fig 21 1391 1401 1321 1331 1791 1841 To Ram Junction Box For 240 VAC Supply Units ...
Страница 40: ...40 310 534 Service Fig 22 1391 1401 1321 1331 1791 1841 To Ram Junction Box For 480 575 VAC Supply Units ...
Страница 42: ...42 310 534 Notes ...
Страница 60: ... 310 534 Electrical Control Panel and Wiring for C32428 240 VAC Lines 100 121 122 122 ...
Страница 64: ...64 310 534 Electrical Control Panel and Wiring for C32428 240 VAC Lines 200 220 ...
Страница 65: ...310 534 65 Notes ...
Страница 66: ... 310 534 Electrical Control Panel and Wiring for C32429 480 VAC 122 122 Lines 100 121 ...
Страница 70: ...70 310 534 Electrical Control Panel and Wiring for C32429 480 VAC Lines 200 220 ...