Service
333492G
19
6.
Install small retaining ring (43), pointer pin (41) and
pointer spring (42). Install the cover (44). (F
. 25).
SDMP8 Preset Meter Counter
Section Repair
Disassembly
NOTE:
Do not disassemble the fluid and counting sec-
tions simultaneously. Confirm the fluid section is fully
assembled before removing the counting section.
1.
Relieve pressure
, page 9.
2.
Remove the cover (44), small retaining ring (43),
(F
. 26).
3.
Remove the needle pointer (41), springs (39) and
pins (40) (F
. 27).
4.
Remove the large retaining clip (38) and then the
face plate panel (37) (F
5.
Use a 2 mm hex wrench to remove the gear set-
screw (33). Remove the gears (32, 34) (F
F
IG
. 25
F
IG
. 26
44
42
43
41
44
43
F
IG
. 27
F
IG
. 28
F
IG
. 29
41
39/40
38
37
33
34
32