Installation
12
333492G
4.
Install extension (102) to meter:
a.
Loosen extension nut (102a) (F
completely off tube threads.
NOTE:
Do not use PTFE tape or thread sealant on
threads of extension (102). This could cause the fitting
to leak.
b.
Thread extension (102) into meter housing as
shown in F
. 5 until it bottoms out.
c.
Align extension (102) with meter housing and
handle. Hand tighten extension nut (102a).
d.
Wrench tighten extension nut (102a).
5.
Install nozzle (101):
NOTE:
Do not use PTFE tape or thread sealant on
threads of nozzle (101). This could cause the fitting to
leak.
a.
Thread nozzle (101) onto extension (102) as
shown in F
.
b.
Use an open-end adjustable wrench on flats of
nozzle bushing (101a) (F
. 7) to tighten fitting.
•
Only
tighten nozzle with wrench on flats of the
nozzle bushing.
•
Do not disassemble the bushing from noz-
zle.
Disassembly will affect performance of the
nozzle.
F
IG
. 4
F
IG
. 5
F
IG
. 6
102a
102
102
F
IG
. 7
101
102
101a