Service
311163ZAH
31
Service
NOTE:
See F
IG
. 16. All models do not use the same
parts. Refer to parts drawing for your model.
Before Servicing
1. Remove the bin from the frame.
2. Follow the
, page 17 or
page 24.
3. Lower the ram plate and deflate the seal.
4. Shut off the air supply to the system.
Replacing Cylinder Bearing
(All Models)
See F
IG
. 16.
1. Follow the
procedure, page 31.
2. Remove screws (409) and washers (410), then take
cylinder guide bearings (408) off the air motor
mounting plate (402).
3. Install cylinder guide bearings (408) on top of the air
motor mounting plate (402), using screws (409) and
washers (410).
NOTE:
The open arch in the cylinder guide bearings
(408) fits around tie rods on the air cylinder (4).
4. Repeat steps 2-3 as needed to replace additional
cylinder bearings.
5. Raise and lower the ram plate to check the bear-
ings.
To avoid injury, always set manual stop latch to
Engage position when working under the plate.
NOTICE
To avoid damaging equipment, replace each bearing
individually. Do not remove all four bearings at the
same time.